Immergas BASIC MAGIS PRO Instructions And Warnings page 98

Single-temperature single-zone hydronic unit with 160-litre storage tank unit
Hide thumbs Also See for BASIC MAGIS PRO:
Table of Contents

Advertisement

Available languages

Available languages

Once the desired parameter is displayed, it is possible to change
the value using the (▶+) or (-◀) keys.
- Maximum temperature in tank 1.
"TkM1" parameter (default value "65°C").
- Maximum value of the desired temperature of the water in tank
1 during normal operation. (Adjustable between +15 and 95°C
with default value 65°C).
- Maximum delta temperature for tank 1
"dtM1" parameter (default value "15°C").
- Difference between temperature T1 of the manifold and tem-
perature T2 of tank 1 to activate main pump 1. (Adjustable
between 3 and 40°C with recommended temperature 7°C).
- Minimum delta temperature for tank 1.
"dtm1" parameter (default value "7°C").
- Difference between temperature T1 of the manifold and tem-
perature T2 of tank 1 to stop main pump 1. (Adjustable between
2 and (tank.1 dTMax -2°C) with recommended temperature
3°C).
- Minimum manifold temperature.
"mtCo" parameter (default value "25°C").
- This setting is used to define a minimum temperature on the
manifold, to authorise the solar charge. (Adjustable between
0°C and 99°C with default value 25°C).
98
1.16
Assembly instructions.
- Wind the heating cable (d13) around the connection pipes and
safety valve.
- The wiring of the antifreeze kit must be connected to the indoor
unit as shown in the relative instruction booklet.
Attention: the graphic representation of the heating cable is
purely indicative.
Minimum temperature -5°C.
The electronics of the indoor unit comes standard with an an-
tifreeze function that activates the electric resistance when the
temperature in the Solar Container or Domus Container falls
below 4°C.
The antifreeze function is only guaranteed if:
- the indoor unit is connected properly to the electrical circuit
and is constantly powered;
- the essential components are not faulty.
In these conditions the product is protected against freezing up to
an ambient temperature of -5°C.
Apertura1
d13
ANTIFREEZE PROTECTION.
46