Immergas BASIC MAGIS PRO Instructions And Warnings page 96

Single-temperature single-zone hydronic unit with 160-litre storage tank unit
Hide thumbs Also See for BASIC MAGIS PRO:
Table of Contents

Advertisement

Available languages

Available languages

1.15
SOLAR CONTROL UNIT
INSTALLATION (OPTIONAL).
If required, it is possible to remove the contact
cover by unscrewing the relevant fixing screw
(Fig. 42) and access the connection area (Fig. 43).
Description of the solar control unit controls.
1: The solar power storage tank is in operation.
2: Simplified system drawing.
- The pump logos switch on when they are
activated.
- The solid triangles on the valve logo indicate
circulation.
- The inside of the tank is active during filling.
3: Operating mode setting.
4: Name of the value or parameter displayed
under number "5".
5: Temperature of the various sensors or value of
the parameter displayed under number "4".
A: Keypad description:
Plus key (▶+);
Minus key (-◀);
Confirmation key or menu navigation key
(OK).
N.B.: on the main screen you can select the sensor
that must always be displayed; press the (OK) key
to display the desired sensor.
Installation menu.
Press the (OK) key for 5 seconds to access the
installation menu.
When you access the installation menu (the first
parameter "Syst" is displayed), it is possible to
select another parameter by pressing the (OK)
navigation key.
Once the desired parameter is displayed, it is
possible to change the value using the keys (▶+)
or (-◀).
Block function.
To prevent errors after installation, all the critical
parameters (system and Extra function) cannot
be accessed when over 4 hours have elapsed after
start-up. If you wish to edit them, disconnect and
reconnect the control unit. No settings are lost
during disconnection or after a blackout.
After 4 hours it is possible to change all the other
settings to optimise the system.
96
8
7
6
Key:
A
Control Unit;
1
Tank 1 sensor (T2) NTC 10k (105°C, 3M);
2
Manifold 1 sensor (T1) PT1000 (180°C, 1.5M);
3
Extra sensor for manifold 2 - (T4) PT1000 (180°C);
4
Extra sensor (T3) NTC 10k (105°C, 3M);
5
Power supply (230 Vac ± 10% - 50Hz);
6
Solar pump (P1);
7
Extra pump or valve (P2);
8
Extra pump or valve (P3) (dry contacts).
2
1
A
5
42
1
2
3
4
43
44