1.11
BASIC MAGIS PRO HYDRAULIC CONNECTION.
Make the hydraulic connection of the Basic Magis Pro, using the
optional kits available and referring to the relative instruction
sheet and to the connection template on the Solar Container and
Domus Container.
Attention: before making the connections, carefully clean the
heating system (pipes, radiators, etc.) with special pickling or
de-scaling products to remove any deposits that could compro-
mise correct operation of the indoor unit and the hydraulic unit.
N.B.: remove all the protection caps on the flow and return pipes
of the hydraulic unit, before making the hydraulic connections.
The connections can be made directly using the couplings on the
hydraulic unit or by inserting system cut-off cocks (optional).
These cocks are particularly useful for maintenance as they allow
you to drain the unit separately without having to empty the
entire system.
Attention: to preserve appliance duration and efficiency features,
we recommend installing a suitable water treatment device if the
water has features that can lead to scale deposits.
1.12
SAFETY VALVE DRAIN.
8 bar domestic hot water safety valve.
Screw the fitting (d9) onto the safety valve. Screw the funnel (d10)
onto the fitting (d9) and convey the outlet to the drains.
3 bar system safety valve.
Connect the silicone pipe (d11) to the drain of the safety valve
in the indoor unit (see the relative instruction booklet) and after
cutting it to size, insert it into the funnel (d10) as shown in
Attention: the drain of the safety valve in the Victrix Hybrid
Plus has been conveyed to the condensate drain trap outlet.
40
1.13
To drain the condensation produced by the Indoor Units, dis-
mantle the relevant pipe on the indoor unit itself and replace it
with the one supplied with the product (longer) and convey the
outlet towards the drains, via suitable pipes that can withstand acid
condensation, with an internal Ø of at least 13 mm. The system
connecting the appliance to the drainage system must be carried
out in such a way as to prevent freezing of the liquid contained in
it. Before product start-up, ensure that the condensate can be cor-
rectly removed. Also, comply with standards in force (UNI 11071)
with national and local regulations on discharging waste waters.
1.14
Refer to the relative instruction booklet for the electrical connec-
tions of the indoor and outdoor units.
• Connecting the DHW probe.
• M a n i f o l d
• Solar control unit electrical connection (optional).
.
Fig. 30
d9
d10
CONDENSATE DRAIN.
ELECTRICAL CONNECTION.
Install the DHW probe on the storage tank unit in the dedicated
seat and connect it to the control panel of the indoor unit as
described in the relative instruction booklet.
s o l a r
connection (optional).
Install the manifold solar probe (supplied in the optional kit)
and connect it to the solar control unit.
Connect the solar control unit to the system as indicated in the
relative instructions manual.
p r o b e
e l e c t r i c a l
41
d11
d10
95