Immergas BASIC MAGIS PRO Instructions And Warnings page 93

Single-temperature single-zone hydronic unit with 160-litre storage tank unit
Hide thumbs Also See for BASIC MAGIS PRO:
Table of Contents

Advertisement

Available languages

Available languages

SOLAR HEATING SYSTEM COUPLING KIT installation
operations.
- Close the cold water inlet upstream of the system and empty the
storage tank unit.
- Disconnect power supply.
- Fix the support bracket (2) for the clip (4) to the hydraulic unit
(A) using the screw (3), (Fig. 38).
- Assemble the plate heat exchanger (5) to the solar unit (1) by
hanging it in the appropriate seat and securing it with the sup-
plied screw (3), (Fig. 37).
- Couple the solar unit (1) to the hydraulic unit (A) by hanging
it to the two appropriate seats, then secure it with the supplied
screws (3), (Fig. 37).
- Stop the expansion vessel using the clip (4) that must be wrapped
around it and passed behind the special bracket (2).
37
1
3
5
- Make the hydraulic connections of the kit (Fig. 39).
- Remove the two caps present on the storage tank unit make
the connections of the relative pipes (UCS and EFS).
- Connect the interception cock (6) on the plate heat exchanger
by interposing the relative flat gasket / seal.
- Following the sequence below, connect all the pipes taking care
to interpose the flat gaskets present in the kit, pipe RP - MP
(long) - UCS - RP (short) - EFS.
- Connect the two solar system pipes to the specially arranged
fittings, using one of the pre-cut slots (B).
- Fit the fitting of the safety valve. Connect the silicone pipe (8)
to the fitting and insert it in the can (7).
- Insert the solar storage tank / cylinder probe (9) in the appro-
priate seat.
- Re-open the cold water inlet and power supply the system again.
38
3
1
3
3
A
4
3
3
2
3
93