Using the pipes inside the accessories box, make the remaining
hydraulic connections between the Storage Tank Unit (a), the
Single-zone hydraulic unit (c) and the Magis Pro V2 Indoor Unit
(P), as shown in Fig. 16.
For easier assembly, start with the pipes closest to the rear wall
up to those closest to the installer, remembering to interpose the
appropriate gaskets supplied.
2
1
AF
The sanitary probe (Fig. 16) must be inserted in the appropriate
seat "1" (Ref. 17 Fig. 47) when the sanitary electrical resistance
is not present.
Otherwise it must be inserted in seat "2" (Ref. 10 Fig. 47).
At the end of the installation, insulate all the connections with the
material present inside the accessories box.
AC
MU
MU
a
RU
P
AF
R
M
c
16
75