Table Of Contents - Immergas MINI NIKE 3 E Technical Manual

Compact wall-hung instantaneous conventional flue boiler
Table of Contents

Advertisement

Technical Documentation
Fault and anomaly signals
The MINI NIKE boiler will signal any anomaly with the
flashing display along with the relative error code as per the
table below:
Anomaly signalled
Safety thermostat block (over-heating), flame control anomaly
Maximum reset N° has been reached
Storage tank probe anomaly (with an optional storage tank
connection kit for the X version)
STMiN3E ed 09/11
Technical Documentation
To eliminate the block (where possible), press the RESET
button (1).
Error code display
01
02
03
04
05
06
08
10
12
15
20
24
27
31
37
38
43
33
Display CAR
V2
ERR 01
ERR 02
ERR 03
ERR 04
ERR 05
ERR 06
Not displayed
ERR 10
ERR 12
ERR 15
ERR 20
ERR 24
ERR 27
ERR 31 / CM
Not displayed
Not displayed
Not displayed
MINI NIKE 3 E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mini nike x 3 eMini nike 24 3 eMini nike x 24 3 e

Table of Contents