Water Valve Resistance Test - BRP Evinrude E-TEC G2 Service Manual

Hide thumbs Also See for Evinrude E-TEC G2:
Table of Contents

Advertisement

Powerhead
Exhaust Water Valve
Results:
An infinite reading (
Isolate the faulty component. Check continuity of
wiring and connections. Repair or replace faulty
wiring.
Signal Circuit
Use the diode test function of a digital multimeter
to check the signal circuit.
Make sure the key switch is OFF.
Connect the BLACK meter lead to the wire listed
in the table, connect the RED meter lead to
engine ground.
Exhaust Water Valve Signal Circuit
(Diode Test)
Wire
BLUE YELLOW
Results:
No reading (OL or
A reading of zero (0) indicates an short circuit.
Isolate the faulty component. Check wiring and
connections. Repair or replace faulty wiring.

Water Valve Resistance Test

Disconnect the battery cables at the battery. Dis-
connect the electrical connector from the exhaust
water valve.
280
) indicates an open circuit.
Pin
Result
approximately
B
0.5 VDC
) indicates an open circuit.
Use a digital multimeter with appropriate test
probe leads to measure the resistance between
the pins of the exhaust water valve connector.
1. Exhaust water valve connector
Exhaust Water Valve Resistance
16 to 18 Ω
Results:
An infinite reading (
of the pump winding.
Replace faulty exhaust water valve.
1
) indicates an open circuit
009468

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

E 250 l ho ag b

Table of Contents