46
SOLAR THERMAL SYSTEM COUPLING KIT (CODE 3.030857)
SOLAR CIRCUIT - Components present in the kit:
• Electronic control unit including 1 storage tank probe (NTC)
and 1 solar collector probe (PT1000);
• Single type solar circulation unit, with 1-6 l/min flow rate
regulator with low power consumption circulator pump and
relative support bracket;
• 6 bar solar safety valve and relative recovery can;
• 18 litre solar expansion vessel with relative support;
• Complete insulated piping for kit installation;
• 16 plate heat exchanger - fully insulated - sized to exchange
the power of max. 2 flat solar collectors (e.g. CP4 XL);
• Thermostatic mixing valve;
• Hydraulic fittings to complete the installation.
NOTE: To complete the solar thermal circuit it is necessary
to provide one or two exclusively flat solar collectors (e.s. CP4
XL/M), solar collector connection kit (including hydraulic fit-
tings and air vent), mount frame and relative mounting system,
98
MAGIS HERCULES PRO
A) SOLAR THERMAL APPENDIX
glycol and connection pipes to the manifold (see pages below
"optional for solar circuit completion").
OPERATING PRINCIPLE:
The kit integrates a plate heat exchanger for exchanging the heat
between the solar collector connected by forced circulation on
the primary side and the domestic hot water on the secondary
side which will be heated by natural circulation.
This technical solution has the advantage of quick heating the
water at relatively high temperatures and directing the heating
water directly to the upper part of the storage tank, thus gener-
ating a readily available volume of water.
The kit is sent partly already assembled and wired, ready to be
fixed inside the MAGIS HERCULES PRO.
The kit also contains the drain fitting, the pipe and can for glycol
collection (conveying the drain of the solar safety valve).