MAGIS HERCULES PRO 12-14-16
35
"POWER" AND "ABSORPTION" IN CENTRAL HEATING MODE
MAGIS HERCULES PRO
16
Air temperature °C
d.b.
(w.b.)
-20
(-21)
-15
(-16)
-10
(-11)
-7
(-8)
-2
(-3)
2
(1)
7
(6)
10
(9)
15
(14)
20
(19)
MAGIS HERCULES PRO
16
Air temperature °C
d.b.
(w.b.)
-20
(-21)
-15
(-16)
-10
(-11)
-7
(-8)
-2
(-3)
2
(1)
7
(6)
10
(9)
15
(14)
20
(19)
MAGIS HERCULES PRO
16
Air temperature °C
d.b.
(w.b.)
-20
(-21)
-15
(-16)
-10
(-11)
-7
(-8)
-2
(-3)
2
(1)
7
(6)
10
(9)
15
(14)
20
(19)
- Correction factor stated DC = 0.9
- TOL = -25 °C
MAGIS HERCULES PRO 16
Water flow temperature °C
25
Max. output
Max. absorbed
(kW)
(kW)
12.58
4.43
14.33
4.68
16.51
4.96
14.90
4.52
14.85
4.00
14.80
3.49
17.28
3.12
18.88
3.15
21.53
3.19
24.19
3.24
Water flow temperature °C
40
Max. output
Max. absorbed
(kW)
(kW)
11.20
5.69
12.89
6.00
14.83
6.29
13.51
6.15
13.22
5.30
12.94
4.44
15.65
4.15
17.13
4.22
19.61
4.26
22.08
4.39
Water flow temperature °C
55
Max. output
Max. absorbed
(kW)
(kW)
12.93
7.59
12.15
7.04
11.43
7.21
10.96
5.86
14.60
5.32
15.11
5.80
17.35
6.00
19.58
6.21
30
Max. output
Max. absorbed
(kW)
(kW)
12.33
4.75
13.93
5.02
16.05
5.32
14.49
4.85
14.44
4.29
14.39
3.74
16.80
3.35
18.35
3.38
20.94
3.42
23.52
3.47
45
Max. output
Max. absorbed
(kW)
(kW)
10.75
6.28
12.52
6.35
14.37
6.60
13.21
6.85
12.70
5.77
12.18
4.68
15.30
4.54
16.79
4.64
19.28
4.80
21.76
4.97
(*) The working points shown in the table refer to peak values.
The nominal working point in the condition:
Temp. Water (M/R) - air (db/wb) = 35/30 - 7/6
Temp. Room = -7°C is:
- Max. output = 12.50
- Max. absorbed = 4.60
- COP = 2.72
35
Max. output
Max. absorbed
(kW)
(kW)
11.65
5.34
13.27
5.64
15.29
5.98
13.80 *
5.45 *
13.75
4.83
13.70
4.20
16.00
3.76
17.48
3.79
19.94
3.85
22.40
3.90
50
Max. output
Max. absorbed
(kW)
(kW)
12.14
6.67
13.94
6.93
12.68
6.95
12.06
6.49
11.57
5.27
14.95
4.93
15.95
5.22
18.31
5.40
20.67
5.59