TECHNICAL DATA MAGIS HERCULES PRO 4 - 6 - 9

Central heating circuit
Power in CH mode with water set at 35 °C
Power in CH mode with water set at 45 °C
Power in CH mode with water set at 55 °C
CH mode COP with water set at 35 °C
CH mode COP with water set at 45 °C
CH mode COP with water set at 55 °C
Flow temperature range
Outdoor temp. limits for Heating mode operation
System integrative resistance absorption (optional)
Cooling circuit
Power in cooling mode with water set at 18 °C
Power in cooling mode with water set at 7 °C
Cooling mode EER with water set at 18 °C
Cooling mode EER with water set at 7 °C
Flow temperature range
Outdoor temp. limits for Cooling mode operation
DHW circuit
V40 - Water mixed at 40°C
Domestic hot water adjustable temperature
Domestic hot water adjustable temperature with
DHW (Domestic hot water) integration resistance
DHW (Domestic hot water) integrative resistance absorption (standard)
DHW (Domestic hot water) integrative resistance absorption (optional)
General data
Max hydraulic system operating
System expansion vessel nominal / (real) capacity
Max operating pressure on the DHW (Domestic hot water) system
Rated DHW expansion vessel capacity
C.H. sound power level
Electric protection rating
Power supply (indoor unit)
Permitted voltage range
Maximum absorbed power (indoor unit)
Absorbed power by the zone 2 or 3 pump (optional)
Maximum absorbed power (outdoor condensing unit)
Refrigerant fluid load (R32)
Water content (in the storage tank)
Condensing outdoor unit empty weight
Indoor unit empty weight
THE REPORTED DATA REFERS TO THE FOLLOWING CONDITIONS (in compliance with EN 14511) :
ROOM
(1)
Water TEMP. (F/R)
- AIR (db/wb)
(2)
Water TEMP. (F/R)
- AIR (db/wb)
(3)
Water TEMP. (F/R)
- AIR (db/wb)
62
MAGIS HERCULES PRO 4-6-9
MHP
kW
(1)
kW
(2)
kW
(3)
(1)
(2)
(3)
°C
°C
kW
kW
(1)
kW
(2)
(1)
(2)
°C
°C
l
°C
°C
kW
kW
bar
litres
bar
litres
dB(A)
IP
V - Hz
V
W
W
W
g
litres
kg
kg
HEATING PHASE (°C)
35/30 - 7/6
45/40 - 7/6
55/47 - 7/6
4
6
4.40
6.00
4.20
5.40
3.90
4.80
5.20
4.92
3.85
3.58
2.95
2.65
20 - 65
20 - 65
- 25 / 35
- 25 / 35
3 (each kit)
3 (each kit)
5.00
6.50
3.60
4.70
4.59
4.42
3.24
3.26
5 - 25
5 - 25
10 / 46
10 / 46
245
244
10 - 55
10 - 55
10 - 65
10 - 65
2.3
2.3
2.3 (each kit)
2.3 (each kit)
3
3
24 / (19.70)
24 / (19.70)
8
8
16
16
58
60
X5D
X5D
230-50
230-50
198-264
198-264
135
135
50 (each kit)
50 (each kit)
2100
2900
1200
1200
56 (235)
56 (235)
46.5
46.5
211
211
COOLING PHASE (°C)
18/23 - 35 (bs)
7/12 - 35 (bs)
9
9.00
8.60
8.00
4.81
3.69
2.93
20 - 65
- 25 / 35
3 (each kit)
8.70
6.50
4.12
3.33
5 - 25
10 / 46
304
10 - 55
10 - 65
2.3
2.3 (each kit)
3
24 / (19.70)
8
16
64
X5D
230-50
198-264
135
50 (each kit)
4300
1400
56 (235)
73.0
211