MAGIS HERCULES PRO 4-6-9
1

MAGIS HERCULES PRO 4 - 6 - 9 FEATURES (SINGLE-PHASE)

Split inverter reversible single-phase air/water heat pumps,
composed of an outdoor condensing unit and an indoor floor
standing unit; a single code identifies the complete system.
Main components:
- Outdoor condensing unit (AUDAX PRO V2) which mainly
includes rotary compressor, inverter electronics, throttle valve,
4-way valve for cycle inversion, finned exchange coil with
outdoor air. The cooling circuit is already preloaded (R32
refrigerant) in the condensing unit, equipped with the relative
shut-off valves;
- Floor standing indoor unit (UI MHP BP), which includes
the hydraulic circuit components for connection to the sys-
tem, as well as the related management and communication
electronics with the condensing unit. The indoor unit can be
divided into 2 parts (with dedicated frame for each individual
unit), to facilitate transportation to the installation rooms; in
particular, it consists of:
72-plate water / R32 Heat exchanger unit;
Stainless steel 235 litre domestic hot water storage tank unit,
standard equipped with 2.3 kW DHW (Domestic hot water)
integrative resistance (possible combination of 1 or 2 additional
2.3 kW DHW (Domestic hot water) resistances - optional);
Stainless steel 45 litre inertial storage tank, which also acts as
a hydraulic manifold;
3 kW System integrative resistance (optional) - only one or 2
can be installed;
Hydraulic unit on the Grundfos CHBL UPM3L K 20-75
primary circuit and 3-way DHW (Domestic hot water) priority
valve, while for the system flow circuits, the zone pumps are
WILO PARA 15-130 7 m (1 standard zone, mixed zone 2 kit
and mixed zone 3 kit, both optional with relative circulators;
the circuits can operate in heating and cooling mode); shut-off
valves with standard filter on zone 1;
24 litre system expansion vessel, 16 litre DHW (Domestic hot
water) expansion vessel;
Electronics including system manager unit (for programming
all generator functions directly from the control panel and
programming the time slots for all circuits and relative climatic
curves, in heating and cooling mode) + power electronics unit
(electrical connection terminal block of the various electrical
devices - e.g. resistances);
Control panel with control covering door equipped with
opening for the large display; controls composed of 7 keys +
2 encoder knobs to make adjustments;
- The system zones can be managed via:
Zone remote panel (optional, for zone 1 also), it is possible to
install up to 3, one for each system zone;
ModBus temperature and humidity sensor kit;
On-off room chrono-thermostat and on-off humidistat;
Variable temperature operation, using the external probe on
the condensing unit. Possibility to set 3 heating curves and 3
cooling curves (from control panel); if the condensing unit is
installed in "unfavourable" conditions for detecting the outdoor
temperature, another external probe can be combined (optional);
BOOST function for DHW (Domestic hot water) - makes it
possible to use all the power available (HP + electrical resist-
ances);
Inlet to force activation with photovoltaic system that produces
electricity (the DHW storage tank is heated to a maximum
storage temperature exclusively by the heat pump. In case of
simultaneous DHW and system request, the system will decide
which service to satisfy, in order to ensure the best comfort);
Electrical outputs for dehumidifier control;
230 V output to control summer/winter diverter valves in
heating systems with fan coil cold / radiant panels; switching
occurs with the change of mode (summer/winter);
Control of Recirculation kit with pump (optional) - pro-
gramming of the activation time slots from control panel +
temperature probe (on the recirculation network return) to
switch off the circulator when the loop is hot;
Programmable anti-legionella function (with resistance);
Screed heater function;
Compared with block heat pumps, the water circuit is fully
protected against freezing because it can be installed inside the
home (important in cold zones);
Minimum system water content demand of 30 litres for ma-
chines up to 9 kW. Therefore, the standard supplied thermal
flywheel (45 litres) is always sufficient.
It is available in the model:
• MAGIS HERCULES PRO 4
• MAGIS HERCULES PRO 6
• MAGIS HERCULES PRO 9
EC Declaration Of Conformity.