Magis Hercules Pro Hydraulic Diagram - Immergas MAGIS HERCULES PRO Manual

Floor-standing split heat pump, with 235 litre integrated dhw domestic hot water storage tank
Hide thumbs Also See for MAGIS HERCULES PRO:
Table of Contents

Advertisement

MAGIS HERCULES PRO
15
8
7
GP
6
5
4
3
2
1
22
KEY:
1
- 16 litre DHW (Domestic hot water)
expansion vessel
2
- 235 litre Stainless steel DHW (Domestic
hot water) storage tank
3
- 2.3 kW DHW (Domestic hot water)
integrative resistance
4
- DHW probe
5
- Outdoor condensing unit
6
- System/DHW (Domestic hot water)
3-way diverter valve
7
- Primary circuit pump
8
- System flow rate meter
9
- Water/gas plate heat exchanger
10 - 3 bar safety valve
11 - 24 litre system expansion vessel
12 - 45 litre inertial storage tank / hydraulic
separator

MAGIS HERCULES PRO HYDRAULIC DIAGRAM

9
10
11
LP
AB
A
B
12
21
20
13 - Y-Filter that can be inspected
14 - One-way valve direct zone 1
15 - Direct zone 1 pump / circulator
16 - Cold water inlet cock
17 - Cold water inlet filter
18 - Flow limiter
19 - Cold water inlet non-return valve
20 - 8 bar safety valve
21 - System filling valve
22 - Storage tank draining valve
LP - Chiller line - liquid phase
GP - Chiller line - gaseous phase
AC - Domestic hot water outlet
AF - Domestic cold water inlet
RZ1 - Direct zone 1 system return
MZ1 - Direct zone 1 system flow
RZ1
MZ1
15
14
13
AC
AF
19
18
17
16
21

Advertisement

Table of Contents
loading

Table of Contents