Remote Control Switch Tests - BRP EVINRUDE E-TEC 200 Service Manual

Table of Contents

Advertisement

REMOTE CONTROL
SWITCH TESTS
Key Switch Test
Refer to Wiring Diagrams at back of manual.
Use an ohmmeter or a continuity light to test key
switch operation. Replace switch if re sults are
incorrect with any of the following tests.
IMPORTANT:
Disconnect ba ttery
switch wiring before proceeding with the following
tests.
Stop/Ground Terminals (M) – Conn ect meter
between the two "M" terminals. Me ter mu st ind i-
cate NO continuity at START or ON.
Turn key switch OFF. Meter must indicate continu-
ity.
Accessory T erminal (A) – Mak e sure the ke y
switch is OFF. Connect the ohmmeter or continu-
ity light between terminals "B" (battery) an d "A"
(accessory) of key switch. Meter must indicate NO
continuity.
Turn switch ON. Meter must indicate continuity.
Turn key switch to START. Meter must continue to
indicate continuity.
Starter Terminal (S) – Hold key switch at START.
Connect meter between terminal "B" and terminal
"S." Meter should indicate continuity.
IMPORTANT:
The cho ke function or ter minal
"C" of the key switch is NOT used.
1
2
1. OFF
2. ON
3. START
Neutral Start Circuit Test
Use an ohmmeter or con tinuity light to test
continuity of th e circu it while p ositioning th e
remote control in NEUTRAL, FOR WARD, an d
REVERSE.
IMPORTANT:
shift cab le to allo w proper re mote cont rol shif t
action while o utboard is not runn ing. Disconnect
the instrument h arness conn ector from the key
switch harness connector.
and ke y
Make sure the remote contro l han dle is in NEU-
TRAL. Connect mete
(red/purple wire) a nd terminal 2 (yellow/red wire).
Turn the key switch to START. Meter must indicate
continuity.
Move the remote con trol hand le to FOR WARD
and turn the key swit ch t o ST ART. Meter must
NOT indicate continuity.
Move the remote control handle to REVERSE and
turn the key switch to START. Meter must NOT
indicate continuity.
3
1. Key switch harness connector
2. Neutral start switch
3. Key switch
IMPORTANT:
instrument ha rness co nnector to key switch h ar-
ness connector.
000443
ELECTRICAL AND IGNITION

REMOTE CONTROL SWITCH TESTS

Turn propeller shaft or disconnect
r between termina l 5
1
3
Reconnect shif t cable an d MWS
the
6
2
000443