4.11 Configuration and Calibration Command List

Following is a list of commands, which will operate in the ADJ and TCICAL mode.
Top-Level Menu Commands
NOTES:
1. Backspace does not function. If a typing error occurs hit Q and begin again.
2. Altitude values 90 to 99 in EEPROM contain factory calibration data and are not customer
accessible.
3. A maximum error of ±499 feet may be introduced at any one altitude.
4. CLR clears all error data in the EEPROM, and returns the digitizer to the original factory calibration.
5. ERR indicates a syntax error.
ADJ <enter>
TCICAL<enter>
Q
Sub-Menu (ADJ) Commands
CLR <enter>
D <enter>
P <enter>
Pabc<enter>
Pab<enter>
Q
Saa<enter>
Action
Enter Adjustment mode.
Enter TCICAL mode.
Quit and resume normal operation.
Clear all EEPROM data.
Display to list all EEPROM error correction table data.
Displays current serial Port settings, see §4.6
Serial Port Software Configuration.
Port protocol assign in ADJ mode, see §4.6 Serial
Port Software Configuration.
Port protocol assign in TCICAL mode. Factory set to
P12. Set to P22 for One-Foot resolution data on TxD4
& TxD5. See §4.7.
Quit and return to top-level commands.
Set digitizer to 1K altitude (aa) mark at current input
pressure. See §4.8 Dynamic Calibration Adjustment
Procedure.