Overvoltage; Inadvertent Spin - Cub Crafters CC11-100 Pilot Operating Handbook

Hide thumbs Also See for CC11-100:
Table of Contents

Advertisement

CUB CRAFTERS
CC11-100

3.3.11 OVERVOLTAGE

If the bus voltage rises above 15.3 volts, the voltage
annunciator will illuminate.
Master Switch ................................................................. Off
Wait one minute. Then, switch the master switch on and
monitor voltage. If the annunciator illuminates again, turn
the master switch off and plan to continue flight without
electrical system.

3.3.12 INADVERTENT SPIN

Aileron Control ......................................................... Neutral
Throttle ..................................................................... Closed
Rudder ............................................................ Full opposite
Elevator ..................................................... Control Forward
Elevator and Throttle ......................................... As required
If flaps were down, retract once a safe flying speed has
been attained. Ensure that the flap speed is not
exceeded (81 mph or 70 knots IAS).
This recovery procedure is applicable only when the
aircraft is in a spin. Application of controls as
described above during a stall or after the aircraft
has stopped gyrating may cause the aircraft to enter
Issued: 08/01/06
Date of Revision: 11/23/18
EMERGENCY PROCEDURES
(Opposite to direction of spin)
(To resume level flight smoothly)
CAUTION
into a spin.
REPORT SC10000AFM
SECTION 3
(To break stall)
Page number: 3-11

Advertisement

Table of Contents
loading

Table of Contents