INSTRUCTIONS FOR
MODELS:
VICTRIX EXA
Installation and maintenance must be performed
in compliance with the regulations in force, ac-
cording to the manufacturer's instructions and
by professionally qualified staff, intending staff
with specific technical skills in the plant sector,
as envisioned by the Law.
Kit installation.
- Remove voltage from the appliance by discon-
necting the switch upstream from the boiler.
- Open the control panel (1) tilting it as pre-
scribed in the boiler instruction booklet.
- Open the control panel (1) (see Figure 6-1)
unscrewing the screws (5) and (4).
5
3
4
2
1
Fig. 6-1
- Perform the electrical connections between the
relay board (6) and the electronic adjustment
card (8) using the two wires present inside the
unit. Connect the external components ac-
cording to requirements following the wiring
diagrams given on the next pages.
- Place the relay board (6) in the dedicated seat
(7).
- Close the control panel (1), paying attention
not to crush the cables present. Re-apply volt-
age to the unit to return to normal operation.
5
7
50
4
6
8