Download Print this page

Immergas 3.015350 Instructions And Warnings page 43

Hide thumbs Also See for 3.015350:

Advertisement

Available languages

Available languages

4
INSTRUCTIONS FOR
MODELS:
MAGIS PRO
MAGIS COMBO
Installation and maintenance must be performed
in compliance with the regulations in force, ac-
cording to the manufacturer's instructions and
by professionally qualified staff, intending staff
with specific technical skills in the plant sector,
as envisioned by the Law.
Kit installation.
- Remove voltage from the appliance by discon-
necting the switch upstream from the boiler.
- Remove the casing of the appliance and tilt
the control panel as shown in its instruction
manual.
3
2
5
7
1
8
Fig. 4-1
- Open the control panel (1) by unscrewing the
screws (3) that hold the cover (2), paying atten-
tion to the rope (4) that supports the weight of
the control panel (1). Once you have removed
the cover, support the control panel (1).
- Assemble the relay board (5), positioning it on
the pins (7) and fasten it with the two cross-
head screws (6) (see Figure 4-1).
- Perform the electrical connections between the
relay board (5) and the electronic adjustment
card (8) using the two wires present inside the
unit. Connect the external components ac-
cording to requirements following the wiring
diagrams given on the next pages.
- Close the control panel (1), re-mount the cas-
ing and re-apply the voltage to the appliance to
take it back to normal functioning conditions.
4
6
3
43

Advertisement

loading