Wiring diagram with several zones.
Using the K1 relay as the ''Main zone control''
and contacts 40 and 41 on the boiler for addi-
tional room thermostats, it is possible to connect
several zones according to requirements. The
Comando Amico Remoto remote control always
controls the main zone (zone 1), whereas the
relative zone valve is always and only managed
Brown
Brown
Blue
Blue
Brown
Brown
Blue
Blue
Fig. 3-3
Wiring diagram with heating phase
active.
The boiler is set up for the management of any
external pump, the pump is powered in concom-
itance with the heating request phase.
All the relays can be configured as an active
Brown
Brown
Blue
Blue
Fig. 3-4
by the K1 relay. Relays 2 and 3 can be used for
one of the functions indicated in the previous
relative tables.
The
Comando Amico Remoto remote control
V2
must be set with On/Off operation, while the
V2
room thermostats require zone valves with end
run contact. The contact must be closed with
valve open hydraulically.
INTEGRATED P.C.B.
INTEGRATED P.C.B.
central heating phase. The diagram represents
the connection on relay 2. In the event this relay
is used, it is necessary to jump pins 57 and 58 of
connector X25 positioned on the relay board.
In addition, the possible connection to relay 1
and relay 3 is represented.
RELAY BOARD
RELAY BOARD
Brown
Brown
Blue
Blue
INTEGRATED P.C.B.
INTEGRATED P.C.B.
Models with Aquaceleris: remove the P.C.B.
to a relay disconnecting connector X5 from the
integrated P.C.B. Then, set relay 3 as "Aquaceleris
PTC Supply Voltage" and connect resistance
"E11" as indicated.
Models with Aquaceleris: remove the P.C.B.
to a relay disconnecting connector X5 from the
integrated P.C.B. Then, set relay 3 as "Aquaceleris
PTC Supply Voltage" and connect resistance
"E11" as indicated.
41
Line
Line
Neutral
Neutral