Download Print this page

Immergas 3.015350 Instructions And Warnings page 35

Hide thumbs Also See for 3.015350:

Advertisement

Available languages

Available languages

2
INSTRUCTIONS FOR
MODELS:
ARES CONDENSING 32
HERCULES
CONDENSING SERIES (*)
VICTRIX SUPERIOR
(*) N.B.: Hercules Condensing 32 ABT excluded.
Installation and maintenance must be performed
in compliance with the regulations in force, ac-
2
2
cording to the manufacturer's instructions and
by professionally qualified staff, intending staff
with specific technical skills in the plant sector,
as envisioned by the Law.
Kit installation.
- Remove voltage from the appliance by discon-
necting the switch upstream from the boiler.
- Disassemble the boiler casing (see instruction
book relative to the boiler model).
- Open the compartment on the control panel
for installation of the relay board (1) (see figure
2-1 on the basis of your boiler model).
- Mount the board making the male pin (2)
Victrix Superior
Ares Condensing 32
4
3
2
1
Hercules Condensing Series
4
3
2
1
- Make the electric connections between the
- Close the control panel, re-mount the casing
35
match the hole in the board (1) and fix it using
the cross-head screw (3) (see figure 2-1 on the
basis of your boiler model).
relay board (1) and the boiler P.C.B. (4) using
the relative wiring composed of two cables
supplied with the kit. Connect the external
components according to requirements fol-
lowing the wiring diagrams given on the next
pages.
and re-apply the voltage to the appliance to
take it back to normal functioning conditions.
Fig. 2-1

Advertisement

loading