Technical Documentation
5
The HERCULES Condensing boiler signals any anomalies
by the flashing symbol (5) along with the "ERRxx" indica-
tion on the indicator (6) where "xx" corresponds to the error
Anomaly signalled
No ignition block
Safety thermostat block (over-heating), flame control
anomaly
Flue safety thermostat block
Contacts resistance block
Flow probe anomaly
Insufficient system pressure
Domestic hot water probe anomaly
Configuration error
Fan anomaly
Parasite flame block
Zones control unit anomaly (displayed only on CAR
or Super CAR remote control when the boiler displays he
errors from 32 to 36)
Return probe anomaly
Push button control panel anomaly
Insufficient circulation
Loss of remote control communication
Low temperature zone 2 probe anomaly
Low temperature zone 3 probe anomaly
Low temp. zone 2 safety thermostat intervention.
Low temp. zone 3 safety thermostat intervention.
IMG Bus communication loss
Low power supply voltage
Loss of flame signal
STHCkW ed 0409
Fault and anomaly signals.
6
code described in the following table. To eliminate the block
(where necessary), press the RESET "C" button positioned on
the boiler panel.
Error code display
ERR 01
ERR 02
ERR 03
ERR 04
ERR 05
ERR 10
ERR 12
ERR 15
ERR 16
ERR 20
ERR from 32 to 36
ERR 23
ERR 24
ERR 27
ERR 31
ERR 32
ERR 33
ERR 34
ERR 35
ERR 36
ERR 37
(displayed only on VIRGILIO palmtop, or inside the "M1"/ "P19"
56
Technical Documentation
Super CAR display
Car display
ERR 01
ERR 02
ERR 03
E02 + E03
ERR 04
E02 + E04
ERR 05
ERR 10
ERR 12
ERR 15
ERR 16
ERR 20
E02 + E20
ERR 22
ERR 23
ERR 24
ERR 27
ERR 31 / CM
E31 / CON
ERR 22
ERR 22
ERR 22
ERR 22
ERR 22
not displayed
not displayed
38
menu)
HERCULES Condensing Export
E01
E02
E05
E10
E12
E15
E16
E22
E23
E24
E27
E22
E22
E22
E22
E22