1st Level
2nd Level
P67
(PUMP
(INTERMIT)
MODE)
P68
(RT DALAY)
P69
(ANTICYC)
P70
(CH RAMP)
P71
(DHW OFF)
P72
(FLOW REG)
RELE1.OFF Relay 1 not used
SERVICE
(BOIL.PAR.)
RELE 1
(optional)
RELE2.OFF Relay 2 not used
RELE 2
(optional)
RELE3.OFF Relay 3 not used
RELE 3
(optional)
P76
(EXT. T.
CORR)
STHCkW ed 0409
M5 Menu (CONFIG)
(an access code must be introduced)
Options
P67.1
In winter mode the boiler pump and that of the main zone are always
(CONTI-
powered and therefore always function
NUE)
P67.2
In winter mode the pumps are managed by the room thermostat or by the
remote control
P67.3
In winter mode the pumps are managed by the room thermostat or by the
(ECO-
remote control and by the boiler flow probe
NOMY)
The boiler is set to ignite the burner immediately after a request for central
0s ÷ 500s
heating. In the case of particular systems (e.g. zone systems with motorised
valves etc.) it could be necessary to delay switch-on
The boiler has an electronic timing device that prevents the burner from
0s ÷ 255s
igniting too often in the central heating phase.
The boiler performs an ignition ramp to arrive from minimum power to
0s ÷ 840s
nominal heat output.
Boiler ignition for heating the domestic hot water occurs when the water
P71.1
contained in the storage tank falls by 3°C with respect to the temperature
(OFF1)
set
(-3 °C)
Solar function deactivated
Boiler ignition for heating the domestic hot water occurs when the water
P71.2
contained in the storage tank falls by 10°C with respect to the temperature
(OFF2)
set
(-10 °C)
Solar function active, if the input domestic hot water has a sufficient tem-
perature the boiler does not switch on
AUTO
OFF
Independently from the options that can be displayed or set, this parameter
8 L/M
does not effect boiler functioning
10 L/M
12 L/M
RELE1.1
In a system divided into zones, relay 1 controls the main zone
The relay signals the intervention of boiler block (Can be coupled to an
RELE1.2
external signalling device, not supplied)
The relay signals that the boiler is on
RELE1.3
(Can be coupled with an external indicator, not supplied)
Controls the opening of an external gas valve in concomitance with an ignition
RELE1.4
request of the boiler burner
Relay 2 activates the remote filling electrovalve (Optional). The control takes
RELE2.6
place from remote control.
The relay signals the intervention of boiler block (Can be coupled to an
RELE2.2
external signalling device, not supplied)
The relay signals that the boiler is on
RELE2.3
(Can be coupled with an external indicator, not supplied)
Controls the opening of an external gas valve in concomitance with an ignition
RELE2.4
request of the boiler burner
RELE2.5
In a system divided into zones, relay 2 controls the secondary zone
Check the storage tank recirculation pump
RELE3.7
(optional pump)
The relay signals the intervention of boiler block (Can be coupled to an
RELE3.2
external signalling device, not supplied)
The relay signals that the boiler is on
RELE3.3
(Can be coupled with an external indicator, not supplied)
Controls the opening of an external gas valve in concomitance with an ignition
RELE3.4
request of the boiler burner
-10°C ÷
If the reading of the external probe is not correct it is possible to correct it in
+10°C
order to compensate any environmental factors
Technical Documentation
Description
54
Value
Default
set by the
value
technician
INTERMIT
0 seconds
180 secondi
840 seconds
(14 minutes)
OFF 1
FIXED ON
AUTO
1 MAIN
2 OFF
3 OFF
0°C