Immergas HERCULES Condensing 26 2 E Manual page 52

Ecological floor-standing condensing boiler with stainless steel storage tank
Hide thumbs Also See for HERCULES Condensing 26 2 E:

Advertisement

Technical Documentation
Below find a list of the various boiler functioning status that
appear on the malfunction display by means of the indicator
(6).
Display (6)
SUMMER
WINTER
DHW ON
CH ON
F3
(ANTIFR.)
CAR OFF
DHW OFF
F4
(POSTFAN)
F5
(POSTCIRC)
P33
(EMERGENCY)
STOP
ERR xx
SET
(DHWSET)
SET
(CH SET)
SET
(OTCCORR)
F8
(AIRPURGE)
F9
(ANTILEG)
STHCkW ed 0409
Description of functioning states
Summer functioning mode in progress without request.
Boiler in stand-by for domestic hot water request.
Winter functioning mode without request in progress.
Boiler in stand-by for domestic hot water or central heating request.
Domestic hot water mode in progress.
Boiler functioning, domestic hot water heating in progress.
Central heating mode in progress.
Boiler functioning, central heating in progress.
Anti-freeze mode in progress.
Boiler functioning to restore the minimum safety temperature against boiler freezing.
Remote Control (Optional) off.
With domestic hot water priority disabled (symbol
mode for duration of 1 hour, however keeping the domestic hot water at minimum temperature (20 °C),
after which the boiler goes back to the normal functioning, previously set.
If used with Super CAR in concomitance with the functioning period in reduced DHW Timer mode,
DHW OFF appears on the display.
The disabled DHW priority function has priority over the anti-legionella function.
Postventilation in progress.
Fan in function after a request for domestic hot water or central heating in order to evacuate residual
fumes.
Postcirculation in progress.
Pump in function after a request for domestic hot water or central heating in order to cool the primary
circuit.
With Remote Control (Optional) or room thermostat (TA) (Optional) in block mode, the boiler func-
tions all the same in CH mode (Can be activated using the "Customisations" menu, it allows to activate the
central heating even if the Remote Control or TA are out of service).
Reset attempts finished.
One hour must pass in order to acquire 1 attempt (See no ignition block).
Anomaly present with relative error code.
The boiler does not function (see troubleshooting paragraph).
During the rotation of the domestic hot water temperature selector switch, view the state of the adjust-
ment of the domestic hot water temperature in progress.
During rotation of the central heating selector switch, view the adjustment status of the boiler flow
temperature for room central heating.
In presence of the external probe (Optional) replace the "SET CH" item.
The value that appears is the correction of the flow temperature with respect to the functioning curve set
by the external probe.
System deaeration in progress.
During this phase, which lasts 18 hours, the boiler pump is started at pre-established intervals, thus al-
lowing deaeration of the heating system.
Only in the case of use with Super CAR, does it allow to activate the anti-legionella function, which
takes the temperature of the water in the storage tank to 65°C for 15 minutes (see Super CAR instruction
book).
Technical Documentation
off), the boiler functions in room central heating
50
HERCULES Condensing Export