Setting menu.
This menu features all the adjustable parameters for your system.
The various parameters are not available on all systems.
To access the Setting menu, press the (-◀) and (▶+) keys at the
same time. When you access the Installation menu (the first
parameter "TkM1" is displayed), it is possible to select another
parameter by pressing the (OK) navigation key.
Once the desired parameter is displayed, it is possible to change
the value using the (▶+) or (-◀) keys.
- Maximum temperature in tank 1.
"TkM1" parameter (default value "65°C").
- Maximum value of the desired temperature of the water in tank
1 during normal operation. (Adjustable between +15 and 95°C
with default value 65°C).
- Maximum delta temperature for tank 1
"dtM1" parameter (default value "15°C").
- Difference between temperature T1 of the manifold and tem-
perature T2 of tank 1 to activate main pump 1. (Adjustable
between 3 and 40°C with recommended temperature 7°C).
- Minimum delta temperature for tank 1.
"dtm1" parameter (default value "7°C").
- Difference between temperature T1 of the manifold and tem-
perature T2 of tank 1 to stop main pump 1. (Adjustable between
2 and (tank.1 dTMax -2°C) with recommended temperature
3°C).
- Minimum manifold temperature.
"mtCo" parameter (default value "25°C").
- This setting is used to define a minimum temperature on the
manifold, to authorise the solar charge. (Adjustable between
0°C and 99°C with default value 25°C).
28
68
1.14
ANTIFREEZE PROTECTION.
Assembly instructions.
- Wind the heating cable (d9) around the connection pipes and
safety valve.
Attention: the graphic representation of the heating cable is
purely indicative.
Minimum temperature 0°C. The pack comes standard with an
antifreeze function that activates the electric resistance when the
temperature in the Container Super Trio falls below 4°C.
The antifreeze function is only guaranteed if:
- the pack is connected properly to the electrical circuit and is
constantly powered;
- the essential components are not faulty.
In these conditions the pack is protected against freezing up to an
ambient temperature of 0°C.