500KLWA CERTIFICATIONS / DISPOSAL
CERTIFICATION DESCRIPTIONS:
500KLWA SCALE DISPOSAL:
®
This Health o meter
Professional scale must be disposed of properly as electronic waste. Follow the national, regional or local
regulations which apply to you for disposal of electronic waste or batteries. Do not dispose of this device in domestic waste.
CUSTOMER SERVICE INFORMATION:
For further information or telephone support, please contact Welch Allyn Customer Service at one of the numbers listed below:
European Call Center - (+353) 46-90-67790
France - (+33) 1-55-69-58-49
Germany - (+49) 695-098-5132
Italy - (+39) 026-968-2425
Netherlands- (+31) 202-061-360
Spain - (+34) 917-499-357
Sweden - (+46) 85-853-6551

SET UP / BATTERIES

INSTALLING BATTERIES
1.
Locate the battery compartment on the back of the display head.
2.
With a Phillips screwdriver remove the screw from the battery compartment cover and remove cover.
3.
Place 6 new AA alkaline batteries into the battery compartment. Make sure the '+' and '-' are positioned correctly, as shown on
the bottom of the battery compartment. Replace batteries when the display reads 'LobAt' (use only 6 AA alkaline batteries).
4.
Replace the battery compartment cover.
Warning: If the scale will not be used for some time, remove batteries to avoid a safety hazard. Disposal of batteries should be in
accordance to your country's national, state or local requirements.
OPERATION WITH ADAPTER POWER
Plug the power adapter into the base of the scale and then into the outlet for power. Please refer to page 3 for information regarding the
adapter required for use with this scale. When an adapter is used, the battery icon will not be displayed. The location of the adapter
power jack on the scale (C) is shown in Figure 1.
ASSEMBLING AND PREPARING THE SCALE FOR USE
1.
Locate cable inside the upper column (A) and then feed it through the lower column (B).
2.
After the cable is fed through (B), then plug the cable into the scale base (C).
3.
Connect columns (A) and (B), then secure to base (C), using the 4 screws provided
(see Figure 1).
4.
Connect upper height rod (E) to lower height rod (F), then slide it into the slot at the
top of the upper column (H).
5.
Turn the scale on by pressing the ON/OFF button. The display will show "Start" and
then "0.0". NOTE: If set up instructions failed, refer to the troubleshooting instructions.
If troubleshooting does not resolve the problem, please contact Health o meter
Professional Technical Support at one of the numbers listed above.
Products carrying this symbol meet the requirements of:
1. Directive governing medical devices 93/42/EEC
0459
Pelstar, LLC has been officially certified as a manufacture of Health o meter
Professional medical devices to be in compliance with stringent legal
requirements. The Pelstar, LLC quality assurance system covers the
development, production, sales and service of medical scales and
measuring systems.
United Kingdom - (+44) 207-365-6780
Latin America - (+1) 305-669-9003
Middle East - (+49) 7477-927186
South Africa - (+27) 11-777-7555
Australia - (+61) 2-9638-3000
China - (+86) 21-6327-9631
®
4
®
Internal Cable
CAUTION
Watch out for pinch points
during assembly that may
damage internal cable
Figure 1