Description
Remote Water Chillers are designed to reduce the temperature of potable water that is routed through the water chiller. This chiller is meant to be
installed in a properly ventilated, non-visible location.
Ratings
•
Electrical: 220VAC, 50Hz, (See nameplate for Amperage), 1 phase.
•
Ambient Air Temperature: 50-100.4 °F (10-38 °C).
•
Water Pressure: 20-100 psig (0.14-0.69 MPa).
•
Maximum Water Temperature: 90 °F (32 °C).
Safety
DANGER
• Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety
precautions in this manual can result in serious injury or death.
• After installation, keep these instructions in a safe location for future reference.
• Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
• Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.
• A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow
electrical disconnection of the unit from electrical supply after installation.
WARNING
• For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before the system.
• Installation and connection to water and electrical mains must be in compliance with local and national laws.
• All Installation and Service work must be performed by an authorized service personnel.
CAUTION
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities
or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children
without supervision.
• To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the
grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The provided
solenoid valve regulator assembly meets this requirement.
Installation / Care / Use Manual
Original Instructions
Model : ECP82WR
220V Refrigeration Package
ECP8_2HWR
•
Refrigerant: HFC-R134a
•
Ingress Protection: IP2x
•
For Indoor Commercial Use only.
PAGE 1
1000004005 (Rev. A - 08/2017)