Download Print this page

Immergas 3.031186 Instruction And Warning Book

Additional kit 2nd mixed zone for magis pro 12-14-16 v2 in super trio top

Advertisement

Available languages

Available languages

Quick Links

COD. 3.031186
KIT AGGIUNTIVO
Foglio istruzioni
IT
2a ZONA MISCELATA
e avvertenze
PER MAGIS PRO 12-14-16 V2
IN SUPER TRIO TOP
ADDITIONAL KIT
2nd MIXED ZONE
FOR MAGIS PRO 12-14-16 V2
Instruction and
IE
IN SUPER TRIO TOP
warning book

Advertisement

loading

Summary of Contents for Immergas 3.031186

  • Page 1 COD. 3.031186 KIT AGGIUNTIVO Foglio istruzioni 2a ZONA MISCELATA e avvertenze PER MAGIS PRO 12-14-16 V2 IN SUPER TRIO TOP ADDITIONAL KIT 2nd MIXED ZONE FOR MAGIS PRO 12-14-16 V2 Instruction and IN SUPER TRIO TOP warning book...
  • Page 2: Avvertenze Generali

    AVVERTENZE GENERALI. - Applicare il coperchio IP (14) al motore tre-vie (15) ed Tutti i prodotti Immergas sono protetti con idoneo imballaggio assemblare sulla valvola miscelatrice, quindi collegarla da trasporto. elettricamente; Il materiale deve essere immagazzinato in ambienti asciutti ed al - premontare il termostato sicurezza (9) mediante le 2 viti (10) riparo dalle intemperie.
  • Page 3 CONTAINER SUPER TRIO COMPOSIZIONE KIT Rif. Q.tà Descrizione Dado ribassato G 1" Guarnizione 21x4 Termometro Coibentazione SX Circolatore Termostato sicurezza Viti di fissaggio Guarnizione 30x22x2 Tubo ritorno impianto seconda zona Coibentazione con velcro Coperchio motore tre vie Motore valvola miscelatrice Valvola miscelatrice Coibentazione valvola miscelatrice Sonda mandata...
  • Page 4 CONTAINER SUPER TRIO CON UNITA' INTERNA MAGIS PRO 12-14-16 V2. Legenda: 1 - Raccordo di scarico 2 - Accumulo 3 - Tappo 4 - Tappo CONTAINER SUPER TRIO CON UNITA' INTERNA MAGIS PRO 12-14-16 V2 CON KIT .
  • Page 5 SCHEMA COLLEGAMENTO CABLAGGIO UNITÀ Una volta effettuato l’assemblaggio del kit proce- INTERNA MAGIS PRO 12-14-16 V2 CON KIT SECONDA dere alla cablatura secondo quanto rappresentato ZONA OPTIONAL IN CONTAINER SUPER TRIO. nello schema elettrico sul libretto istruzioni. - Collegare i cavi nel cruscotto dell'Unità Interna Magis Pro 12-14-16 V2 come previsto in Fig.
  • Page 6 SCHEMA ELETTRICO ALLACCIAMENTO MAGIS PRO 12-14-16 V2.
  • Page 7 2 - Eliminare il ponte X40-1 prima del collegamento elettrico del termostato ambiente zona1 3 - 230 Vac - 50 Hz 4 - Valvola 2 punti 5 - Connessione collaudo Immergas 6 - Aperto/Chiuso 7 - Chiuso 8 - Aperto...
  • Page 8 POMPA DI CIRCOLAZIONE DI ZONA. • Altre funzioni: - La funzione di sfiato della pompa si attiva premendo a lungo L’apparecchio è fornito di due circolatori: il circolatore per zona (3 secondi) il tasto di comando ed esegue automaticamente 1 diretta e circolatore per zona 2 miscelata. lo sfiato della pompa.
  • Page 9 Guasti, cause e rimedi. Guasti Cause Rimedi Pompa non funzionante Fusibile elettrico difettoso Controllare i fusibili con alimentazione di La pompa è priva di tensione Eliminare l'interruzione dell'alimentazione di tensione corrente inserita. Aumentare la pressione del sistema entro in campo consenti- La pompa genera dei Cavitazione a causa di una pressione di rumori...
  • Page 10 Prevalenza disponibile all'impianto zona 1 diretta prevalenza proporzionale 1000 1200 1400 1600 1800 2000 2200 2400 2600 3000 2800 Legenda: X1 = Portata (l/h) A = Prevalenza disponibile Y1 = Prevalenza (kPa) B = Potenza assorbita dal circolatore (area tratteggiata) Y2 = Potenza assorbita circolatore (W) Prevalenza disponibile all'impianto zona 1 diretta prevalenza costante 1000...
  • Page 11 Prevalenza disponibile all'impianto zona 1 diretta velocità costante 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Legenda: X1 = Portata (l/h) A = Prevalenza disponibile Y1 = Prevalenza (kPa) B = Potenza assorbita dal circolatore (area tratteggiata) Y2 = Potenza assorbita circolatore (W) Prevalenza disponibile all'impianto zona 2 miscelata prevalenza proporzionale 1000...
  • Page 12 Prevalenza disponibile all'impianto zona 2 miscelata prevalenza costante 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Legenda: X1 = Portata (l/h) A = Prevalenza disponibile Y1 = Prevalenza (kPa) B = Potenza assorbita dal circolatore (area tratteggiata) Y2 = Potenza assorbita circolatore (W) Prevalenza disponibile all'impianto zona 2 miscelata velocità...
  • Page 13 SCHEMA IDRAULICO COLLEGAMENTO UNITA' INTERNA MAGIS PRO 12-14-16 V2 CON KIT SECONDA ZONA MISCELATA IN CONTAINER SUPER TRIO. Legenda: AC - Uscita acqua calda sanitaria 1 - Valvola miscelatrice 3 vie AF - Entrata acqua fredda sanitaria 2 - Termostato sicurezza MZ2 - Mandata impianto zona miscelata 3 - Circolatore zona miscelata RZ2 - Ritorno impianto zona miscelata...
  • Page 14: General Warnings

    This instruction manual provides technical information for it with the lock nut (5); installing the Immergas kit. As for the other issues related to kit installation (e.g. safety at the workplace, environmental protection, - connect the system return pipe (12) to the mixing valve...
  • Page 15: Kit Composition

    CONTAINER SUPER TRIO KIT COMPOSITION Ref. Q.ty Description Lowered nut G 1" Gasket 21x4 Thermometer Circulator LH insulation Safety thermostat Fixing screws Gasket 30x22x2 Second zone system return pipe Velcro insulation Three-way motor cover Mixing valve motor Mixing valve Mixing valve insulation Flow probe Clip Second zone flow pipe...
  • Page 16 CONTAINER SUPER TRIO WITH INDOOR UNIT MAGIS PRO 12-14-16 V2. Key: 1 - Drain fitting 2 - Accumulation 3 - Cap 4 - Cap CONTAINER SUPER TRIO WITH INDOOR UNIT MAGIS PRO 12-14-16 V2 WITH KIT.
  • Page 17 WIRING DIAGRAM FOR MAGIS PRO 12-14-16 V2 Once the kit is assembled, proceed with the INDOOR UNIT WITH OPTIONAL SECOND ZONE KIT wiring according to the wiring diagram in the IN CONTAINER SUPER TRIO. instruction booklet. - Connect the cables in the control panel of the Magis Pro 12-14-16 V2 Indoor Unit as shown in Fig.
  • Page 18 MAGIS PRO 12-14-16 V2 WIRING DIAGRAM.
  • Page 19 2 relay board (optional) 2 - Eliminate jumper X40-1 before electrical connection of the zone1 room thermostat 3 - 230 Vac - 50 Hz 4 - 2-point valve 5 - Immergas test connection 6 - Open/Close 7 - Close 8 - Open...
  • Page 20 ZONE CIRCULATION PUMP. • Other functions: The device is equipped with two circulator pumps: the circulator - The vent function of the pump is activated by pressing and holding (3 seconds) the control key and automatically venting for direct zone 1 and the circulator for mixed zone 2. the pump.
  • Page 21: Troubleshooting

    Troubleshooting. Faults Causes Solutions Faulty electrical fuse Check the fuses Pump not working with power supply on. The pump is without voltage Eliminate the power supply cut-off Increase the system pressure within the allowed field The pump generates Cavitation due to insufficient flow pres- noise sure Check the head setting and eventually set a lower head...
  • Page 22 Total head available to the system of zone 1 direct proportional head 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Key: X1 = Flow rate (l/h) A = Total head available Y1 = Head (kPa) B = Power absorbed by the system pump (dotted area) Y2 = Circulator pump absorbed power (W) Total head available to the system of zone 1 direct constant head 1000...
  • Page 23 Total head available to the system of zone 1 direct constant speed 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Key: X1 = Flow rate (l/h) A = Total head available Y1 = Head (kPa) B = Power absorbed by the system pump (dotted area) Y2 = Circulator pump absorbed power (W) Total head available to the system of zone 1 mixed proportional head 1000...
  • Page 24 Total head available to the system of zone 1 mixed constant head 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Key: X1 = Flow rate (l/h) A = Total head available Y1 = Head (kPa) B = Power absorbed by the system pump (dotted area) Y2 = Circulator pump absorbed power (W) Total head available to the system of zone 1 mixed constant speed 1000...
  • Page 25 HYDRAULIC DIAGRAM FOR THE CONNECTION OF THE INDOOR UNIT MAGIS PRO 12-14-16 V2 V2 WITH MIXED SECOND ZONE KIT IN CONTAINER SUPER TRIO. Key: AC - Domestic hot water outlet 1 - 3-way Mixing valve AF - Domestic cold water inlet 2 - Safety thermostat MZ2 - Mixed zone system flow 3 - Mixed zone pump / circulator...
  • Page 28 N.B.: correct periodic maintenance is highly recommended. Il libretto istruzioni è realizzato in carta ecologica This instruction booklet is madeof ecological paper. Immergas TOOLBOX L’App studiata da Immergas per i professionisti The App designed by Immergas for professionials Disponibile su Disponibile su Disponibile su immergas.com...