Download Print this page
Elkay EZO Series Installation, Care & Use Manual
Elkay EZO Series Installation, Care & Use Manual

Elkay EZO Series Installation, Care & Use Manual

Hide thumbs Also See for EZO Series:

Advertisement

Quick Links

EZO4*1E
EZO8*1E
INSTALLATION, CARE & USE MANUAL
Manual de Instalación, Cuidado y Utilización
Manuel d'installation/entretien/utilisation
EZO™ Series Barrier-Free Water Coolers
EZO™ La Barrera de la serie Liberta Agua Coolers
EZO™ Coolers d'Eau de Barrière-Libère de feuilleton
Page 1
98940C (Rev. C - 12/16)

Advertisement

loading

Summary of Contents for Elkay EZO Series

  • Page 1 EZO4*1E EZO8*1E INSTALLATION, CARE & USE MANUAL Manual de Instalación, Cuidado y Utilización Manuel d’installation/entretien/utilisation EZO™ Series Barrier-Free Water Coolers EZO™ La Barrera de la serie Liberta Agua Coolers EZO™ Coolers d’Eau de Barrière-Libère de feuilleton Page 1 98940C (Rev. C - 12/16)
  • Page 2 EZO4*1E EZO8*1E Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad. Remarque : Danger ! Risque d'électrocution. Débrancher avant de réparer l'appareil. Uses HFC-134A refrigerant Usa refrigerante HFC-134A Utilise du fluide frigorigéne HFC-134A 3, 4 Sensor Eye...
  • Page 3 EZO4*1E EZO8*1E FIG. 2 Page 3 98940C (Rev. C - 12/16)
  • Page 4 EZO4*1E EZO8*1E HANGER BRACKETS & TRAP INSTALACIÓN DE LOS SOPORTES INSTALLATION DES SUPPORTS FIJADORES Y EL PURGADOR DE SUSPENSION ET DU SIPHON INSTALLATION Retire el soporte fijador que se encuentra conectado a 1) Retirez le support de suspension fixé au dos du 1) Remove hanger bracket fastened to back of cooler la parte posterior del enfriador sacando un (1) tornillo.
  • Page 5 EZO4*1E EZO8*1E Service Instructions Bubbler Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Page 6: Entretien

    EZO4*1E EZO8*1E SENSOR RANGE ADJUSTMENT: The electronic sensor used in this cooler is factory pre-set for a “visual” range of 36 inches (914 mm). If actual range varies greatly from this or a different setting is desired, follow the range adjustment procedure below: Using a small tip screwdriver, locate range adjustment screw through the small hole between the sensor lenses (See Page 1.) Turn this screw clockwise to increase range and counterclockwise to decrease range (See Fig.
  • Page 7: Cleaning The Strainer

    EZO4*1E EZO8*1E Cleaning the strainer To clean the strainer, unscrew the cap of the solenoid valve. Remove screen and rinse thoroughly with water. Insert screen back into solenoid valve and screw cap on. Make sure the o-ring is placed properly. Screen Limpieza del filtro Malla...
  • Page 8 IMPRESO EN LOS E.E.U.U. NÚMERO GRATIS DE SERVICIO 1.800.260.6640 IMPRIMÉ AUX É.-U. INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 Page 8 98940C (Rev. C - 12/16)

This manual is also suitable for:

Ezo4 1e seriesEzo8 1e series