Tubular bottle filler fountain with sanitary freeze resistant single valve control assembly (10 pages)
Summary of Contents for Elkay 4400FR Series
Page 1
4400FR_FTN_A LK4400FR_FTN_A Owners Manual Model 4400FR Tubular Fountain with Sanitary Freeze Resistant Single Valve Control Assembly INSTALLER 4400FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
4400FR_FTN_A LK4400FR_FTN_A INSTALLATION INSTRUCTIONS IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING.
Page 3
4400FR_FTN_A LK4400FR_FTN_A SUGGESTED SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING THE SANITARYFR1 VALVE 4" PVC 1/4 BEND 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS 4"...
Page 4
4400FR_FTN_A LK4400FR_FTN_A SUGGESTED SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING THE SANITARYFR1 VALVE (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER 1-1/4 DRAIN TUBE SUPPLIED WITH FTN. AIR GAP ASSY. O 14" 356mm SUPPLIED WITH VALVE 10"...
Page 5
4400FR_FTN_A LK4400FR_FTN_A FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector.
4400FR_FTN_A LK4400FR_FTN_A The Following Items are included with the SanitaryFR1 Valve PARTS LIST ITEM NO. PART NO. DESCRIPTION 110175443890 Hex Nut - 3/8-16 45806C Single Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4” (Cut To Length) - To Bubbler 56123C Poly Tubing - 1/8”...
4400FR_FTN_A LK4400FR_FTN_A TROUBLESHOOTING AND MAINTENANCE Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
Page 9
Included with Sanitary Valve PRINTED IN U.S.A. FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816 Halsey Taylor – halseytaylor.com 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523 Elkay – elkay.com PAGE 9 1000003951 (Rev. A - 06/17)