Removing the Inverter Cover
To remove the inverter cover
1. Switch off the AC circuit breaker on the main distribution panel.
2. Switch off the inverter ON/OFF/P switch and wait 5 minutes for the internal
capacitors to discharge.
3. Open the Allen screws of the inverter cover and carefully pull the cover horizontally
before lowering it.
4. Open the inverter cover.
CAUTION!
When removing the inverter cover, make sure not to damage the internal
components. SolarEdge will not be held responsible for any components
damaged as a result of incautious cover removal.
Removing the Connection Unit Cover (if applicable)
1. Switch off the AC circuit breaker on the main distribution panel and the safety
switch (if applicable).
2. Open the DC Safety Unit cover: Release the four Allen screws and remove the cover.
CAUTION!
When removing the DC Safety Unit cover, make sure not to damage the internal
components. SolarEdge will not be held responsible for any components
damaged as a result of incautious cover removal.
Single Phase Energy Hub Inverter MAN-01-00812-1.1
Chapter 7: Setting Up Communication with the Monitoring Platform
Figure 20: Communication board connectors
51