2.1 IMPORTANT ADVICE.
Inspecting and handling the unit.
Upon delivery, check the packaging and immedi-
ately report any damage to the shipping company.
2.2 TECHNICAL SPECIFICATIONS.
Maximum operating temperature
Minimum operating temperature
Relative humidity
Minimum cooling water inlet temperature
Maximum cooling water inlet temperature
Water pH
Cooling / Heating
2.3 ACCESSORIES PROVIDED.
Make sure the package contains all of the instal-
lation accessories.
Name
ST3.9x25 screw for installation
panel
Plastic foam pipe
Wrapping tape
Drain pipe
Wall-mounted pipe cover
Remote control (with operating
manual)
Remote control mount
Assembly screw (ST2.9
10-C-H)
Alkaline batteries (AM4)
Cable for ON/OFF switch
Installation manual
Gasket
Consider the following when handling the unit:
Fragile, handle with care.
• Choose the route for transporting the unit in
advance.
• Move the unit in its original packaging, if
possible.
• Use special protective devices when lifting the
unit so as not to damage the belts, and pay
attention to the position of the unit's centre
of gravity.
Inside temperature
Water inlet temperature
Figure
27
We recommend you strictly follow these in-
structions.
The product warranty is rendered null and void
if the above instructions are not complied with.
The manufacturer declines any liability for any
faults to the product resulting from transport or
handling not complying with the above recom-
mendations.
1.6 Mpa
0.15 Mpa
< 90% (normal 0 ~ 80%)
3°C
70°C (normal 50°C)
6.5 ~ 7.5
17°C ~ 32°C / 0°C ~ 30°C
3°C ~ 20°C / 30°C ~ 70°C
Quantity
8
Fixing the installation panel
8
1
1
1
1
1
Mount for the remote control
Installing
2
mount
2
For the remote control
1
1
This manual
4
For connecting the water pipe
Function
the
remote
control

Advertisement

Table of Contents
loading

Table of Contents