Immergas HYDRO Instructions And Warnings page 25

Wall-mounted hydronic water kit
Table of Contents

Advertisement

Available languages

Available languages

1.2 INSTALLATION.
Read this "Installation paragraph"
to correctly install the device.
Strictly follow these instructions to
install the indoor unit or its pipes.
If the fan coil is to be installed on a
metal part of the building, it needs to
be electrically isolated in compliance
with the applicable regulations on
electrical appliances.
When all installation operations have
been completed, carefully check and
connect the supply voltage.
If the product is improved or mod-
ified, this manual will be subject to
variations without forewarning.
The fan coil must be installed in com-
pliance with national wiring regula-
tions to avoid the risk of death.
Make sure the device is installed,
repaired or serviced only by experi-
enced and qualified staff.
Incorrect installation, repairs or main-
tenance can cause electric shock, short
circuit, water leaks, fires or otherwise
damage the device.
Strictly follow the instructions in
this manual to install the appliance.
Incorrect installation of the device
can cause water leaks, electric shocks
or fires.
Use the accessories provided and the
specified parts for installation.
Otherwise this could cause a water
leak, an electric shock or a fire.
Install the unit on a steady, strong
support that can withstand the
weight of the device.
Otherwise the unit could fall and
cause damage and injury.
The unit must be installed at 2.3 m
off the ground.
The unit must not be installed in the
laundry room.
Before opening the terminals, dis-
connect all supply voltage circuits.
Place the unit so that the power
socket is accessible.
The case must bear the flow direc-
tion of the fluid, either in words or
symbols.
In the event of water leaks during in-
stallation, immediately ventilate the
area.
When installation is complete, make
sure there are no water leaks.
The temperature of the cold water in
the unit must not be less than 3°C,
while that of the water must not ex-
ceed 70°C. The water in the unit must
be clean and the air quality must com-
ply with the PH standard=6.5~7.5.
This device is not intended for use
by persons (including children)
with reduced physical, sensory or
mental abilities, with no experience
or knowledge, unless supervised or
helped by a person responsible for
their safety.
As the circuit temperature is high,
install the connection cable away
from copper pipes.
Take all necessary precautions dur-
ing installation in the event of strong
winds, typhoons or earthquakes.
Improper installation can cause the
unit to fall and damage property or
injure people.
Do not install the fan coil in:
- Environments containing petrola-
tum.
- Environments with salty air (near
coasts).
- Environments with caustic gases
(e.g. sulphur) in the air (near spa
areas).
- Environments subject to strong
voltage variations (in factories).
- Busbars or cabinets.
- Kitchens with large amounts of
diesel.
- Environments with strong electro-
magnetic waves.
- Environments with flammable
materials or gas.
- Environments with acidic or alka-
line liquids in evaporation.
- Other particular conditions.
25
When installation is complete, make
sure the unit works properly when
started up.
Provide the customer with all informa-
tion required for correct operation and
maintenance of the unit.
Order of installation:
- Choose the installation point;
- Install the indoor unit;
- Install the pipes;
- Install the drain pipe;
- Connect the vent pipe;
- Wire the unit;
- Test operation.