Download Print this page
Elkay 4590 Series Owner's Manual

Elkay 4590 Series Owner's Manual

Freeze resistant barrier free stone pedestal fountain
Hide thumbs Also See for 4590 Series:

Advertisement

Quick Links

4590 Freeze Resistant Barrier Free Stone Pedestal Fountain
PLEASE READ THE FOLLOWING
• INSTALLATION INSTRUCTIONS FOR THE 4590FR FTN.
WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE
LOCATED ON PAGES 2 - 5.
• INSTALLATION INSTRUCTIONS FOR THE 4590FR FTN.
WITH SANITARYFR1 VALVE ARE LOCATED ON PAGES
6 - 12.
INSTALLER
4590 Fountains are among the easiest to install Fountains on the market today. To assure you
install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE
WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave
these instructions with the Fountain for future reference.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A
COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS
GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A
METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF
PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
4590FR_FTN LK4590FR_FTN LK4590SFR_FTN
Owners Manual
STOP!
INFORMATION.
IMPORTANT
IMPORTANT
PAGE 1
96812C (Rev. SID - 1/11)

Advertisement

loading

Summary of Contents for Elkay 4590 Series

  • Page 1 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN Owners Manual 4590 Freeze Resistant Barrier Free Stone Pedestal Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. • INSTALLATION INSTRUCTIONS FOR THE 4590FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED ON PAGES 2 - 5. • INSTALLATION INSTRUCTIONS FOR THE 4590FR FTN. WITH SANITARYFR1 VALVE ARE LOCATED ON PAGES 6 - 12.
  • Page 2 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN Owners Manual 4590 Freeze Resistant Floor Mounted Barrier Free Stone Fountain with 97243C Single Valve Control Assembly IMPORTANT! INSTALLER PLEASE NOTE Do not pull up on lines coming out of the PVC column. This raises the water valve above the frost line with disastrous results.
  • Page 3 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN SITE PREPARATION DETAIL FOR THE 4590FR FTN. WHEN USING 97243C SINGLE VALVE CONTROL ASSY. LEGEND F = 1-1/4" DRAIN TUBE A = ACCESS PANEL G = AIR CONTROL LINE B = REMOVABLE BOTTOM COVER C = 1" PVC DRAIN H = 1/4"...
  • Page 4: Troubleshooting

    4590FR_FTN LK4590FR_FTN LK4590SFR_FTN INSTALLATION INSTRUCTIONS FOR INSTALLING 97243C SINGLE VALVE CONTROL ASSY. 1. Prepare trench for water supply and waste drain lines (if required by local codes). The hole should be deep enough to accommodate the PVC column and 5 cubic feet of porous fill (large broken rock).
  • Page 5 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN The following items are included with the 4590FR Fountain 10-B 6, 10-A PARTS LIST ITEM NO. PART NO. DESCRIPTION Drain Gasket 100147140560 Gasket 100322740560 Clamp - Hose 101449542550 Drain Gasket 101570540560 Bubbler Tube Assy. 15013C Set Screw #8-32 x .125 110544942550 Socket Head Screw #10-24 x .75 110868642550...
  • Page 6: General Installation Tips

    4590FR_FTN LK4590FR_FTN LK4590SFR_FTN Owners Manual 4590 Freeze Resistant Barrier Free Stone Pedestal Fountain with SanitaryFR1 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1.
  • Page 7 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4590FR FTN. WHEN USING THE SANITARYFR1 VALVE FIG. 1 PAGE 7 96812C (Rev. SID - 1/11)
  • Page 8 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4590FR FTN. WHEN USING THE SANITARYFR1 VALVE FIG. 2 LEGEND A = ACCESS PANEL B = REMOVABLE BOTTOM COVER 96812C (Rev. SID - 1/11) PAGE 8...
  • Page 9 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector.
  • Page 10 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN Stream Height Adjustment 3, 11 See Detail B FIG. 5 FIG. 4 Detail B 96812C (Rev. SID - 1/11) PAGE 10...
  • Page 11 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN The Following Items are included with the SanitaryFR1 Valve PARTS LIST DESCRIPTION PART NO. ITEM NO. 110175443890 Hex Nut - 3/8-16 45806C Single Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4” (Cut To Length) - To Bubbler 56123C Poly Tubing - 1/8”...
  • Page 12 4590FR_FTN LK4590FR_FTN LK4590SFR_FTN The Following Items are included with Trouble Shooting the 4590FR Fountain Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. PARTS LIST Clean rubber orifice in flow control located below frost line in bushing between barb ITEM NO.

This manual is also suitable for:

4590fr_ftnLk4590fr_ftnLk4590sfr_ftn4590fr ftn seriesLk4590fr ftn seriesLk4590sfr ftn series ... Show all