ENGINE COVER SERVICE
LOWER COVER SERVICE

Latch Handle Installation

Apply a light coat of Triple-Guard grease to latch
handle shaft. Insert handle into lower cover.
1. Triple-Guard grease
Apply Ultra-Lock to screw threads. Place spring
washer and hook into position and tighten screw
to a torque of 180 in. lbs. (20 N·m).
90

Trim Switch Installation

Place switch into position through cover.
1
006827
Install nut on switch. Tighten nut to a torque of 10
to 16 in. lbs. (1 to 2 N·m).
Install electrical connector. Refer to CONNEC-
006821
TOR SERVICING on p. 156.
006746
006747
006748