Cooling System; Flushing - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

MAINTENANCE

COOLING SYSTEM

COOLING SYSTEM
Check the condition of cooling system compo-
nents regularly:
water intake screens
water pump
all internal water passages
thermostats
all external water hoses and fittings
vapor separator cooling passages and fittings
EMM cooling passages and fittings
overboard water pressure indicator.

Flushing

Flush the outboard with fresh water following each
use in brackish, salt, or polluted water to minimize
the accumulation of scale and silt deposits in cool-
ing system passages.
The outboard can be flushed on the trailer or at
dockside; running or not running.
The outboard must be located in
IMPORTANT:
a well ventilated area with appropriate ground
drainage during the flushing procedures.
Keep water inlet pressure between 20 to 40 psi
(140 to 275 kPa).
Flushing — Outboard Running
WARNING
To prevent injury from contact with rotat-
ing propeller, remove the propeller before
flushing.
Refer to Propeller Hardware Installation on
p. 65.
Place outboard in VERTICAL (DOWN) position in
a well ventilated area.
74
Remove plug and nozzle (overboard indicator)
from the flushing port.
Thread garden hose into flushing port.
Shift the outboard to NEUTRAL with the propeller
removed.
Turn water supply on.
START outboard. Run it at IDLE only.
Shut OFF the outboard. Turn off water supply and
remove garden hose.
Reinstall plug and nozzle. Position the plug and
nozzle to allow the water stream to be seen from
the helm.
Leave the outboard in VERTICAL (DOWN) posi-
tion long enough for the powerhead to drain com-
pletely.
Reinstall propeller.
004263