Tachometer Pulse Setting; Water Pump Overboard Indicator; Break-In - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

Tachometer Pulse Setting

Confirm accuracy of tachometer reading.
Adjust dial on back of tachometer to required
setting (the outboard should not be running).
Outboard Model
40–300 HP

Water Pump Overboard Indicator

A steady stream of water should flow from the
overboard indicator.
1. Water pump overboard indicator
Tachometer Setting
6 Pulse or 12 Pole
1
DRC4952
INSTALLATION AND PREDELIVERY
Operating Temperature
An outboard run at idle speed should achieve a
temperature based on the engine's thermostatic
control. In general, the powerhead temperature
should reach at least 104°F (40°C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature. Refer to specific SERVICE
SPECIFICATIONS on p. 10.
Idle Speed
Make sure the outboard idles within the specified
idle RPM range. If the outboard is run on a flush-
ing device, the idle speed and quality may not be
representative of actual in water use.

Break-In

When the outboard is delivered, refer the cus-
tomer to the break-in information in the Opera-
tor's Guide.
The Engine Management Module (EMM) auto-
matically supplies extra oil to the engine during
the first two hours of operation, above 2000 RPM.
Use the diagnostics software to confirm that the
break-in program has been started. Refer to Oil
Control Settings on p. 104.