BRP E250DHLSCS Service Manual page 381

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

TROUBLE CHECK CHART
OUTBOARD WILL NOT START
OBSERVATION
Outboard does not
turn over
Outboard turns slowly
POSSIBLE CAUSE
Battery switch not ON
Discharged battery
Battery cables and connections
Faulty connection or ground,
damaged electrical harness
Fuse (10 A)
Wiring harness
Key switch
Starter solenoid
Starter or bendix/drive gears
Seized powerhead or gearcase Check and repair as needed
Discharged battery
Battery cables and connections
Powerhead hydro-locked
Partially seized powerhead or
gearcase
Starter or bendix/drive gears
TROUBLE CHECK CHART
OUTBOARD WILL NOT START
PROCEDURE
Check battery switch operation
Check battery, recharge or replace
Clean and tighten connections. Check for voltage
drop in starter circuit.
Check all grounds, connections and wiring
Check wiring, then replace faulty fuse
Check for 12 V at terminal "B" of key switch
Check key switch operation
Check wiring and test solenoid
Check starter, inspect bendix/drive gears
Check battery, recharge or replace
Clean and tighten connections. Check voltage
drop in starter circuit.
Check cylinders for water
Check and repair as needed
Check starter, inspect bendix/drive gears
T–1