Adjustments - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

Fill the reservoir to the bottom of the fill hole with
Power Trim/Tilt & Steering Fluid. Install and
tighten the reservoir cap. Turn the manual release
valve in until it seats. Cycle the unit up and down
several times to purge air.
Operate the unit to the full UP position, then run
down momentarily to release pressure. Check the
fluid level again and add fluid, if necessary.
Remember that all rods must be completely up to
check the fluid level. Test the unit by performing
the Pressure Leakdown Test on p. 323.
Check the tilt rod bushings. Replace them if they
are worn excessively.
Check the bushings on the bottom of the manifold
body. Replace them if they are worn excessively.
41859
Check system operation in both trim and tilt range.

ADJUSTMENTS

Refer to Trim Sending Unit Adjustment on
p. 67.
Refer to Tilt Limit Switch Adjustment on p. 66.
41885
TRIM AND TILT
ADJUSTMENTS
41888
41878
14
343

Advertisement

Table of Contents
loading

This manual is also suitable for:

E250dhxscsE300dpxscsE300dcxscsE300dpzscsE300dczscs

Table of Contents