INSTALLATION AND PREDELIVERY
BOAT RIGGING
Battery Switch Operation
Select the primary battery for normal operation.
•
Secondary batteries should only be selected for
•
emergency starting.
ALL or BOTH switch position is for emergency
•
starting only.
Provide operator with the documentation sup-
plied by the battery switch manufacturer. Make
sure that the operator is informed of proper
battery switch operation.
The negative (–) terminals of a
IMPORTANT:
multiple 12-volt battery installation must be con-
nected together.
1
1. Starting battery (primary)
2. Accessory battery (secondary)
3. Cable connecting negative (–) battery terminals
30
Auxiliary Battery Charging
Evinrude E-TEC V4–V6 outboards are equipped
with isolated battery charging capability. The iso-
lated charge connection must only be used to
charge a single 12-volt battery or two 12-volt bat-
teries wired in parallel.
IMPORTANT:
tery isolator to the stator of an Evinrude E-TEC
outboard.
Accessory Charge Lead Kit, P/N 5006253, is
routed from a connector on the outboard's electri-
cal panel to the accessory battery.
3
1. Accessory battery charge connector
IMPORTANT:
2
never be connected to any battery of a 24-volt
DRC7284
electrical system.
Never connect an external bat-
1
The accessory charging kit must
003912