Water Pump Service - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

GEARCASE

WATER PUMP SERVICE

35 to 40 ft. lbs. (47 to 54 N·m). For adjustment,
refer to Trim Tab Adjustment on p. 68.
1. Trim tab screw
2. Index mark
Standard rotation and counter
IMPORTANT:
rotation trim tabs must not be interchanged. This
would result in inadequate cooling water supply to
the propeller hub.
Place the shift rod in the shift rod lever. Install the
retaining pin and washer. Tighten pin to a torque
of 60 to 84 in. lbs. (7 to 9.5 N·m).
1. Shift rod screw
WARNING
To prevent loss of operator control, check
for proper shifting operation and adjust, if
necessary.
During break-in period of a reas-
IMPORTANT:
sembled gearcase, change the gearcase lubricant
between 10 to 20 hours of operation.
274
WATER PUMP SERVICE
Disassembly
Rotate the driveshaft counterclockwise to unlock
the impeller cam. Remove the four impeller hous-
ing screws.
1
1
2
1
COA3663
1. Screws
Slide the water pump off the driveshaft. Remove
the impeller drive cam, O-ring, impeller plate, and
gasket. Discard the gasket.
2
1
004241
1. O-ring
2. Impeller plate
Remove all the parts from the housing.
Inspection
Check impeller for overheating, hub separation,
and other wear or damage.
Check liner and wear plate for scoring, distortion,
and impeller material transfer.
Inspect the housing for cracks or melting.
1
31998
1
006870