Fuel System Tests; Fuel System Pressure Test - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

FUEL SYSTEM

FUEL SYSTEM TESTS

FUEL SYSTEM TESTS
WARNING
Use caution when working on any pres-
surized fuel system. Wear safety glasses
and work in a well ventilated area. Extin-
guish all smoking materials and make cer-
tain no open flames or ignition sources
exist. Before starting any fuel system ser-
vice, carefully relieve fuel system pres-
sure. Failure to properly relieve fuel
system pressure can result in spraying
fuel and/or excessive fuel spillage during
servicing. Fuel is flammable and can be
explosive under certain conditions.

Fuel System Pressure Test

Relieve fuel system pressure. See Relieving Fuel
System Pressure on p. 174.
WARNING
Protect against hazardous fuel spray.
Before starting any fuel system service,
carefully relieve fuel system pressure.
After relieving fuel system pressure, install a 0 to
60 psi (0 to 415 kPa) Fuel Pressure Gauge,
P/N 5007100 or equivalent, to the upper fuel pres-
sure test fitting.
2
1. Fuel pressure gauge
2. Test fitting
START outboard and check pressure. System
pressure should be 20 to 35 psi (138 to 241 kPa).
170
Shut OFF outboard. Monitor pressure gauge.
Pressure should not drop below 15 psi (103 kPa).
IMPORTANT:
fuel system and crank outboard; check circulation
pump operation; check fuel system pressure.
Results:
Normal pressure
Observe pressure reading after outboard is shut
OFF.
Refer to Lift Pump Pressure Test on p. 172.
Pressure drops after outboard is shut OFF:
Check for leaking fuel injector.
Check for leaking pressure regulator.
Check for external fuel system leak.
High pressure:
Check for restricted filter or fuel return fitting of
vapor separator, damaged pressure regulator in
vapor separator, or restricted fuel return mani-
fold.
Low pressure
Check fuel supply to fuel lift pump. Refer to Lift
Pump Vacuum Test on p. 173. Higher vacuum
readings indicate restrictions in the fuel supply.
Repair or replace as needed.
Restricted fuel filter/water separator assembly.
Lift pump not supplying adequate fuel to vapor
separator. Refer to Lift Pump Pressure Test
on p. 172.
If the above tests are good and vapor separator
remains full of fuel, check for damaged circula-
tion pump. Replace vapor separator assembly.
No pressure
1
Check electrical circuit and ground connections
for circulation pump.
If voltage is present and pump does not run,
repair connection or replace vapor separator
assembly.
Relieve fuel system pressure before removing fue
004324
pressure gauge. Refer to Relieving Fuel System
Pressure on p. 174.
If outboard does not run, prime