BRP E250DHLSCS Service Manual page 162

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

ELECTRICAL AND IGNITION
CONNECTOR SERVICING
Terminal Installation
Install wire gasket on wires and feed wires
through the correct terminal position of the con-
nector housing. Terminal is crimped onto wire and
then pulled back into connector housing until lock-
ing tab engages and terminal is seated.
002304
Crimping Terminals
Strip insulation back 3/16 in. (5 mm). Position end
of wire strands in terminal past the wire crimp area
and the end of insulation in the insulation crimp
area of the terminal.
Capture all wire strands in crimp; leave no loose
strands. Crimp wire and insulation securely using
crimping pliers.