BRP E250DHLSCS Service Manual page 161

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

Terminal Installation
Align terminal with connector housing and push
terminal with seal into connector housing until
seated.
2
1. Latch
2. Terminal with seal
Packard
Connectors
Always
IMPORTANT:
meter test probes and adapters when testing com-
ponents fitted with these terminals.
Disconnect
Lift latch(s). Remove connector.
Connect
Confirm the seal is in place. Push connector onto
housing until latched.
1
002456
use
the
appropriate
ELECTRICAL AND IGNITION
CONNECTOR SERVICING
Terminal Removal
A tab on the back side of the terminal engages a
shoulder in the connector housing to hold the ter-
minal in place. The terminal is removed by push-
ing wire and terminal through connector housing.
Insert a thin wire, such as a paper clip, into the
connector above the terminal to release tab.
TYPICAL
Terminal Tool
DRC5940
7
DRC5941
159

Advertisement

Table of Contents
loading

This manual is also suitable for:

E250dhxscsE300dpxscsE300dcxscsE300dpzscsE300dczscs