Connector Servicing - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

ELECTRICAL AND IGNITION

CONNECTOR SERVICING

CONNECTOR
SERVICING
DEUTSCH Connectors
IMPORTANT:
Electrical
mended. Incorrect grease application can cause
electrical or warning system problems.
To disconnect the connector, press the latch and
pull the connectors apart.
To connect the connector, confirm that the seal is
in place. Clean off any old grease and dirt from
connectors. Apply a light coat of Electrical Grease
to seal. Push connectors together until latched.
1
1. Latch
2. Seal
Terminal Removal
Use
hook-end
of
P/N 342667, to pull out wedge from receptacle, or
use other end of tool to pry out wedge from plug.
Use needle-nose pliers to remove wedge from
3-pin receptacle.
1. Wedge
156
is
recom-
Grease
Connector
Service
Release terminal latch and gently pull on wire.
1
1. Terminal latch (receptacle)
2. Terminal latch (plug)
Terminal Installation
Push terminal through seal until it locks into place.
Fill connector with Electrical Grease to 1/32 in.
(0.8 mm) below ledge or end of plug.
2
1
42079A
1. Ledge of plug
2. End of plug
Push wedge in until latched. Wedge in 2-pin
receptacle is not symmetrical; position latch shoul-
Tool,
ders next to terminals.
Crimping Terminals
Strip insulation back 3/16 in. (5 mm). Place termi-
nal in 18-gauge notch of Crimping Pliers,
P/N 322696. Position end of wire strands in termi-
nal past wire crimp area, and position end of insu-
lation past insulation crimp area. Capture all wire
strands in crimp; leave no loose strands. Crimp
1
wire securely. Do not solder. Crimp insulation in
14/16-gauge notch of crimping pliers.
2
42327
3
1. End of wire strands
2. Insulation crimp area
3. End of insulation
4. Wire crimp area
2
42329
2
42330
1
4
DRC6205

Advertisement

Table of Contents
loading

This manual is also suitable for:

E250dhxscsE300dpxscsE300dcxscsE300dpzscsE300dczscs

Table of Contents