ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS

Dynamic Information

Dynamic information is viewed while the outboard
is running. Changes in data, such as voltages or
temperatures, are shown as they happen.
Engine Monitor Screen

Stored Service Codes (Faults)

Service codes are stored if an abnormal condition
occurs while the outboard is running.
The Stored Faults screen of the diagnostics soft-
ware shows the code number, the number of
times the event occurred, and operating hours of
first and last occurrences.
Stored Faults Review Screen
102

Hard Faults

A hard fault is a service code that currently exists.
Hard faults become stored faults only if the out-
board is running.
006958
Hard Faults Review Screen

Persistent Faults

The Persistent Faults screen keeps a history of all
previously stored codes, including code number,
the number of times the event occurred, and oper-
ating hours of the last occurrence.
Persistent faults cannot be erased.

Static Tests

Static Tests allow diagnostic testing of system
components while the outboard is NOT running.
006625
Static Tests Screen