Immergas VICTRIX TERA VIP Instructions And Warnings

Immergas VICTRIX TERA VIP Instructions And Warnings

Hide thumbs Also See for VICTRIX TERA VIP:
Table of Contents

Advertisement

Quick Links

VICTRIX TERA
Instructions and warnings
IE
Installer
VIP
User
Maintenance technician

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX TERA VIP

  • Page 1 VICTRIX TERA Instructions and warnings Installer User Maintenance technician...
  • Page 2: Table Of Contents

    Maintenance function (MA)..........54 1.11 External temperature probe (Optional)......15 3.17 "Chimney sweep” function..........54 1.12 Immergas ue systems............16 3.18 Solar panels coupling function........55 1.13 Tables of resistance factors and equivalent lengths of 3.19 Pump anti-block function.
  • Page 3: Dear Customer

    Dear Customer, Congratulations for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas Customer, you can also count on an Authorised A er-Sales centre, prepared and updated to guarantee constant e ciency of your boiler.
  • Page 5: Safety Symbols Used

    SAFETY SYMBOLS USED. GENERIC HAZARD Strictly follow all of the indications next to the pictogram. Failure to follow the indications can generate hazard situa- tions resulting in possible harm to the health of the operator and user in general. ELECTRICAL HAZARD Strictly follow all of the indications next to the pictogram.
  • Page 6: Boiler Installation

    ATTENTION: e Victrix Tera Vip boiler has been designed for wall mounted installation only; for central heating and check the environmental operating production of domestic hot water for domestic use conditions of all parts relevant to in- and similar purposes.
  • Page 7 - Installation of gas appliances, ue ex- It is just as important that the intake grids and exhaust terminals are not obstructed. haust pipes and combustion air intake It is recommended to check that no ue gas recircula- pipes is forbidden in places with a re tion is found in the air sample points (0.5% maximum risk (for example: garages, closed parking permitted CO...
  • Page 8 Risk of damage due to corrosion caused by unsuitable ATTENTION: combustion air and environment. - Type B open chamber boilers must not Spray, solvents, chlorine-based detergents, paints, glue, be installed in places where commer- ammonium compounds, powders and similar cause cial, artisan or industrial activities take place, product and ue duct corrosion.
  • Page 9: Main Dimensions

    MAIN DIMENSIONS. Key: V - Electrical connection G - Gas supply AC - Domestic hot water outlet AF - Domestic hot water inlet SC - Condensate drain (minimum internal diameter Ø 13 mm) R - System return M - System ow Height Width (mm) Depth (mm)
  • Page 10: Antifreeze Protection

    An aqueous solution must be made with potential pollution class of water 2 (EN 1717:2002). e materials used for the central heating circuit of Immergas boilers resist ethylene and propylene glycol based antifreeze liquids (if the mixtures are prepared perfectly).
  • Page 11: Cycloidal Lter Unit

    CYCLOIDAL FILTER UNIT. - Place a container under the lter to collect the water contained e magnetic cycloidal lter is standard supplied in the boiler. in it. Allows to detect the ferrous residues present in the system's water. - Remove the clip and pull out the magnetic cartridge by pulling anks to the two cocks it facilitates maintenance by cleaning the it downwards.
  • Page 12: Gas Connection

    (i.e. downstream from the pipes connecting the system to the appliance), according to the manufacturer’s instructions. e Immergas connection unit, supplied as an optional kit, also includes the gas cock, whose installation instructions are provided in the kit.
  • Page 13: Hydraulic Connection

    In order to meet the system requirements established by EN 1717 in terms of pollution of drinking water, we recommend installing the IMMERGAS anti-back ow kit to be used upstream of the cold water inlet connection of the boiler. We also recommend using a category 1, 2 or 3 heat transfer uid (ex: water + glycol) in the boil- er’s primary circuit (CH circuit), as de ned in standard EN 1717.
  • Page 14: Electrical Connection

    A er-sales Service. It is recommended to contact ATTENTION: a quali ed company (e.g. the Immergas Authorised A er-Sales the manufacturer declines any respon- Technical Assistance Service) for replacement to avoid a hazard.
  • Page 15: External Temperature Probe Optional

    44/40 and 41 eliminating jumper X40 (Fig. 37). Make sure that the On/O thermostat contact is “dry”, i.e. independent of the mains voltage, • On/O Immergas digital chrono-thermostat. otherwise the P.C.B. would be damaged. Any Comando Amico e chrono-thermostat allows:...
  • Page 16: Immergas Ue Systems

    1.12 IMMERGAS FLUE SYSTEMS. Immergas supplies various solutions separately from the boilers regarding the installation of air intake terminals and ue exhaust, which are fundamental for boiler operation. ATTENTION: the boiler must be installed exclusive- ly with an original Immergas “Green Range”...
  • Page 17: Tables Of Resistance Factors And Equivalent Lengths Of 3.19 "Green Range" Ue System Components

    1.13 TABLES OF RESISTANCE FACTORS AND EQUIVALENT LENGTHS OF “GREEN RANGE” FLUE SYSTEM COMPONENTS. Resistance Length TYPE OF DUCT Factor in m of concentric pipe Ø 80/125 Concentric pipe 80/125 Ø m 1 Ø 80/125 90° concentric bend Ø 80/125 45° concentric bend Terminal complete with concentric horizontal intake-exhaust Ø...
  • Page 18 Resistance Length Length Length Length TYPE OF DUCT Factor in m of concen- in metres in metres in m of concen- tric pipe Ø 60/100 of a Ø 80 pipe of a Ø 60 pipe tric pipe Ø 80/125 Intake m 7.3 Concentric pipe Ø...
  • Page 19: Outdoor Installation In Partially Protected Area

    - the ue exhaust must be connected to its own single chimney ) or ducted directly outside via a vertical terminal for direct exhaust (B ) or via an Immergas ducting system (B e technical regulations in force must be respected. Cover kit assembly (Fig. 13).
  • Page 20 e cover kit includes: e terminal kit includes: N° 1 ermoformed cover N° 1 Gasket N°1 Gasket clamping plate N° 1 Exhaust ange Ø 80 N°1 Gasket N° 1 Ø 80 90° bend N°1 Gasket tightening clip N° 1 Exhaust pipe Ø 80 N°1 Intake hole covering plate N°...
  • Page 21: Concentric Horizontal Kit Installation

    100. In this case the special extensions must be requested. Immergas also provides a Ø 60/100 simpli ed terminal, which in combination with its extension kits allows you to reach a maxi- mum extension of 11.9 metres.
  • Page 22 e kit includes: N° 1 - Gasket (1) N° 1 - Concentric bend Ø 60/100 (2) N° 1 - Int./exhaust concentric terminal Ø 60/100 (3) N° 1 - Internal wall sealing plate (4) N° 1 - External wall sealing plate (5) e adaptor kit includes: N°...
  • Page 23: Concentric Vertical Kit Installation

    1.16 CONCENTRIC VERTICAL KIT INSTALLATION. • Type C con guration, sealed chamber and fan assisted. Concentric vertical intake and exhaust kit. is vertical terminal is connected directly to the outside of the building for air intake and ue exhaust. N.B.: the vertical kit with aluminium tile enables installation on terraces and roofs with a maximum slope of 45% (approx 25°) and the height between the terminal cap and half-shell (374 mm for Ø...
  • Page 24 e Kit includes: N° 1 - Gasket (1) N° 1 - Female concentric ange (2) N° 1 - Wall sealing plate (3) N° 1 - Aluminium tile (4) N° 1 - Int./exhaust concentric pipe Ø 60/100 (5) N° 1 - Fixed half-shell (6) N°...
  • Page 25: Separator Kit Installation

    1.17 SEPARATOR KIT INSTALLATION. Type C con guration, sealed chamber and fan assisted. • Separator kit Ø 80/80. is kit allows air to come in from outside the building and the exhaust to exit from the chimney, ue or intubated duct through divided ue exhaust and air intake pipes.
  • Page 26 * - C e kit includes: N° 1 - Exhaust gasket (1) N° 1 - Flange gasket (2) N° 1 - Female intake ange (3) N° 1 - Female exhaust ange (4) N° 2 - Ø 80 90° bend (5) N°...
  • Page 27: Adaptor C9 Kit Installation

    1.18 ADAPTOR C9 KIT INSTALLATION. Kit Assembly. is kit allows an Immergas boiler to be installed in "C " con g- - Mount the components of kit "C9" on the door (A) of the ducting uration, with combustion air intake directly from the sha where system (Fig.
  • Page 28 Technical data. e dimensions of the sha s must ensure a minimum gap be- tween the outer wall of the smoke duct and the inner wall of the sha : 30 mm for circular section sha s and 20 mm in the event of a square section sha (Fig.
  • Page 29: Ducting Of Ues Or Technical Slots

    Ø80 complete exhaust terminal, 1m of Ø 80 pipe in exhaust, two of the regulations in force. 90° Ø 80 bends at boiler outlet for connecting to the ducting Immergas ducting system. system and two direction changes of the exible hose inside the chimney/technical slot.
  • Page 30: Con Guration Type B, Open Chamber And Fan Assisted For Indoors

    1.20 CONFIGURATION TYPE B, OPEN CHAMBER AND 1.22 FLUES, CHIMNEYS, CHIMNEY POTS AND FAN ASSISTED FOR INDOORS. TERMINALS. e appliance can be installed inside buildings in B or B mode; e ues, chimneys and chimney caps for the evacuation of com- in this case, all technical rules and national and local regulations bustion products must be in compliance with applicable standards.
  • Page 31: System Lling

    1.23 WATER TREATMENT SYSTEM FILLING. As already mentioned in the previous paragraphs, a treatment of the thermal and domestic system water is required, in compliance with the local standards in force. e parameters that in uence the duration and proper oper- ation of the heat exchanger are the water's PH, total hardness, conductivity, and oxygen, together with the system's processing residues (any welding residues), any oil present and corrosion...
  • Page 32: Boiler Start Up Ignition

    1.27 BOILER START UP IGNITION . If necessary, the bypass can be regulated to system requirements To commission the boiler (the operations listed below must only be from minimum (bypass closed) to maximum (bypass open). performed by quali ed personnel and in the presence of sta only): Adjust using a at-head screwdriver.
  • Page 33 Pump release. If a er a long period of inactivity, the circulator is blocked, adjust the screw in the centre of the head in order to manually release the motor sha . Take great care during this operation to avoid damage to the motor. Bypass Regulation (Part.
  • Page 34: Kits Available On Request

    1.30 KITS AVAILABLE ON REQUEST. • System shut-o valve kits without inspection lter (on request). e boiler is designed for installation of system interception cocks to be placed on ow and return pipes of the connection assembly. is kit is particularly useful for maintenance as it allows the boiler to be drained separately without having to empty the entire system.
  • Page 35: Boiler Components

    1.31 BOILER COMPONENTS. Key: 1 - Aqua Celeris device air vent cock / tap 17 - Condensation module 2 - Aqua Celeris 18 - Venturi 3 - Ignition/detection electrode 19 - Return probe 4 - Air intake pipe 20 - Fan 5 - Flow probe 21 - System pressure switch 6 - Aqua Celeris Resistance...
  • Page 36: Instructions For Use And Maintenance

    INSTRUCTIONS FOR USE AND • Do not open or tamper with the ap- MAINTENANCE. pliance. GENERAL WARNINGS. • Do not take apart or tamper with the ATTENTION: intake and exhaust pipes. • Never expose the wall-mounted boiler • Only use the user interface devices listed in to direct vapours from a cooking sur- this section of the booklet.
  • Page 37 - do not use electrical switches, plugs, door professionally authorised company as required bells, telephones or intercom devices in the by current legislation. Contact the manufac- building; turer for disposal instructions. - call an authorised company (e.g. Immergas A er-Sales Service).
  • Page 38: Cleaning And Maintenance

    CLEANING AND MAINTENANCE. To preserve the boiler's integrity and keep the safety features, performance and reliability, which distin- guish it, unchanged over time, you must execute maintenance operations on a yearly basis in com- pliance with what is stated in the relative point at “annual check and maintenance of the appliance”, in compliance with national, regional, or local standards in force.
  • Page 39: Using The Boiler

    2.4 USING THE BOILER. e boiler is supplied as per standard with Aqua Ce- Before ignition make sure the heating system is lled with water leris device function deactivated to safeguard energy and that the manometer (8) indicates a pressure of 1 - 1.2 bar. consumption.
  • Page 40: Fault And Anomaly Signals

    (1) (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical A er-Sales Service) (2) The anomaly can only be verified in the list of errors in the “Information” menu...
  • Page 41 (1) probes temperature dri detected (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical A er-Sales Service) (2) The anomaly can only be verified in the list of errors in the “Information” menu...
  • Page 42: Information Menu

    INFORMATION MENU. By pressing the button “ “, the “Information menu” is activated for at least 1 second, displaying some boiler operating parameters. To scroll through the various parameters, press the buttons “DHW regulation” “ “. With the menu active on the indicator (19) the parameter via the letter “d”...
  • Page 43: Boiler Shutdown

    Periodically check the system water pressure. e boiler pressure anti-freeze liquid and installation of the Immergas Antifreeze Kit gauge should read a value of between 1 and 1.2 bar. in the boiler. In the case of prolonged inactivity (second case), we...
  • Page 44: Instructions For Maintenance And Initial Check

    With regard to the above, only use Immergas original spare parts when replacing parts. If additional documentation needs to be consulted for extraordinary maintenance, contact the Authorised Immergas A er-Sales Service.
  • Page 45: Yearly Appliance Check And Maintenance

    Intervention time must be less than 10 seconds. the combustion chamber. It is also forbidden to use alkaline or acid detergents. Victrix Tera Vip - Check the integrity of the insulating panels inside the com- at nominal at minimum bustion chamber and if damaged replace them.
  • Page 46: Hydraulic Diagram

    3.4 HYDRAULIC DIAGRAM. Key: 16 - System expansion vessel 1 - Cycloidal lter unit 31 - By-pass 17 - Aqua Celeris device air vent cock / tap 2 - Gas valve 32 - Draining cock / tap 18 - Flue sample point (F) 3 - D.H.W.
  • Page 47: Wiring Diagram

    Earth FRAME 230 vac power supply 50Hz Key: Colour code key: B1 - Flow probe BK - Black BL - Blue B2 - DHW probe B4 - External probe (optional) BR - Brown B5 - Return probe G - Green GY - Grey B9 - DHW inlet probe (optional) OR - Orange...
  • Page 48: Possible Problems And Their Causes

    Clean the above components e gas conversion operation must be carried out by and ensure correct installation of the terminal, check correct an authorised company (e.g. Immergas A er-Sales Technical setting of the gas valve (O -Set setting) and correct percentage Assistance Service).
  • Page 49: Calibration Of Fan Speed

    (does not detach from burner); S1 = 121 (6050 rpm) Maintenance interventions must be carried out by S1 = 127 (6350 rpm) G230 an authorised company (e.g. Immergas A er-Sales Technical Assistance Service). ADJUSTMENT. Attention: the CO veri cation operations must be carried out...
  • Page 50: Programming The P.c.b

    3.11 PROGRAMMING THE P.C.B. e rst digit of the central indicator (19) shows the family of the e boiler is prepared for possible programming of several operation parameter, while the second digit shows its number. By pressing parameters. By modifying these parameters as described below, the the domestic hot water / D.H.W.
  • Page 51 Custom- Param- Parameter Description Range Default ised value eter Max DHW De nes the maximum heat output percentage of the boiler during the 0 - 100 % 100 % output D.H.W. phase compared to the maximum heat output available Min CH output De nes in percentage the minimum output in central heating mode 0 - P2 G20 = 85 De nes the maximum heat output percentage of the boiler during the central...
  • Page 52 Custom- Param- Parameter Description Range Default ised value eter Establishes the display lighting mode. 0 : the display lights up during use and lowers a er 15 seconds of inactivity. Display In the case of anomaly the display ashes. 0 - 2 lighting 1 : display lighting o .
  • Page 53: Password-Protected Special Functions

    3.12 PASSWORD PROTECTED SPECIAL FUNCTIONS. e function is activated from boiler in o mode by pressing and Attention: the boiler is equipped with some special functions, access holding the buttons “Reset”, “Info” and “Stand-by” for more tan to which is granted if this is in stand-by ( 5 seconds.
  • Page 54: Flue Installation Fu

    3.15 FLUE INSTALLATION FU . 3.17 "CHIMNEY SWEEP” FUNCTION. To activate the “Flue” function access the special functions as When activated, this function forces the boiler to variable described in Par. 3.12 and select the “FU” function. output for 15 minutes. In this state all adjustments are excluded and only the safety Attention: before performing the test, ensure that the condensate thermostat and the limit thermostat remain active.
  • Page 55: Solar Panels Coupling Function

    3.18 SOLAR PANELS COUPLING FUNCTION. e boiler is prepared to receive pre-heated water from a system of solar panels up to a maximum temperature of 65°C. In any case, it is always necessary to install a mixing valve on the hydraulic circuit upstream of the boiler, on the cold water inlet.
  • Page 56: Casing Removal

    3.22 CASING REMOVAL. • Front panel (Fig. 52). To facilitate boiler maintenance the casing can be completely 4) Open the door (e1), remove the cover caps (c) and loosen screws removed as follows: (d). • Lower grid (Fig. 51). 5) Pull the front panel (e) towards you and release it from its lower 1) Loosen the two screws (a).
  • Page 57 • Control panel (Fig. 54). • Sides (Fig. 55). 9) Press the hooks on the side of the control panel (i). 11) Loosen screws (k) of side fastening (j). 10) Tilt the control panel (i) towards you. 12) Remove the sides by extracting them from their rear seat (Ref. X). Rif.
  • Page 58: Technical Data

    TECHNICAL DATA. VARIABLE HEAT OUTPUT. N.B.: the power data provided in the table are obtained with 0.5 m long intake/exhaust pipe. Gas ow rates refer to net calori c value at a temperature of 15°C and at a pressure of 1013 mbar. METHANE (G20) PROPANE (G31) PROP.
  • Page 59: Technical Data Table

    TECHNICAL DATA TABLE. Domestic hot water nominal heat input kW (kcal/h) 28.8 (24773) Central heating nominal heat input kW (kcal/h) 24.6 (21194) Minimum heat input kW (kcal/h) 4.5 (3862) Domestic hot water nominal heat output (useful) kW (kcal/h) 28.3 (24295) Central heating nominal heat output (useful) kW (kcal/h) 24.1 (20717)
  • Page 60: Key For Data Nameplate

    KEY FOR DATA NAMEPLATE. Cod. Md Sr N° Cod. PIN Type Qnw/Qn min. Qnw/Q max. Pn min. Pn max. Class CONDENSING N.B.: the technical data are provided on the data plate on the boiler Model Cod. Md Model code Sr N° Serial Number Check Cod.
  • Page 61: Technical Parameters For Combination Boilers In Compliance With Regulation 813/2013

    Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY (*) High temperature mode means 60°C on return and 80°C on ow. (**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return...
  • Page 62 PRODUCT FICHE IN COMPLIANCE WITH REGULATION 811/2013 . Parameter value punto soluzioni srl Annual energy consumption for the central heating "!! VICTRIX TERA VIP 44.0 GJ mode (Q Annual electricity consumption for the domestic hot 27 kWh water function (AEC) Annual fuel consumption for the domestic hot water 18.0 GJ...
  • Page 63: Parameters For Lling In The Package Che

    In case you should wish to install an assembly, starting from the devices, integration heat pumps, temperature controllers). Victrix Tera Vip boiler, use the assembly charts in (Fig. 58 and 61 Use board (Fig. 58) for “assemblies” related to the central heating To complete it properly, ll the relevant spaces (as shown in the mode (e.g.: boiler + temperature controller).
  • Page 64 Parameters for lling in the assembly chart. Parameter Victrix Tera Vip ‘I’ ‘II’ ‘III’ 1.11 ‘IV’ 0.44 * to be established by means of table 5 of Regulation 811/2013 in case of “assembly” includ- ing a heat pump to integrate the boiler. In this case the boiler must be considered as the main appliance of the assembly.
  • Page 65 Facsimile for lling in the domestic hot water production system package che. :DWHU KHDWLQJ HQHUJ\ HI¿FLHQF\ RI FRPELQDWLRQ ERLOHU ‘I’ Stated ORDG SUR¿OH Solar contribution )URP WKH ERDUG RI WKH VRODU GHYLFH Auxiliary electricity ( 1.1 x ‘I’ 10 % ) ‘II’...
  • Page 66 Parameters for lling in the DHW package che. Parameter Victrix Tera Vip ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 811/2013 and transient calculation methods as per Notice of the European Community no. 207/2014. Domestic hot water production system package che.
  • Page 68 Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 IMMERGAS SPA - ITALY CERTIFIED COMPANY UNI EN ISO 9001:2015 Design, manufacture and post-sale assistance of gas boilers, gas water heaters and related accessories...