Specifications; Dimensions; Electrical Specifications Power Supply - Record K21 User Manual

Table of Contents

Advertisement

4

Specifications

4
Specifications
4.1

Dimensions

U = interior diameter
A = passage width
Q = total exterior diameter (incl.
canopy)
T = exterior diameter (drum wall)
S = centre passage width
I = canopy height with dust roof
I = canopy height with integrated
roof pan
I = canopy height with air curtain
G = passage height
J = total height
LH = light height
((shell dimensions)
LB = light width
((shell dimensions)
Optionally, intermediate dimensions are also possible in the range from 3200 mm to 7000 mm.
4.2

Electrical specifications power supply

Mains voltage
Nominal power
Fuse
Safety class
NOTICE
The power connection must be installed by a licensed electrician. One must be able to turn
the power supply off completely via a main switch or residual current circuit breaker.
24 / 44
3600 mm 4200 mm 4800 mm 5400 mm 6000 mm 6600 mm 7200 mm
2005 mm 2347 mm 2688 mm 3030 mm 3371 mm 3713 mm 4055 mm
3758 mm 4358 mm 4958 mm 5558 mm 6158 mm 6758 mm 7358 mm
3652 mm 4252 mm 4852 mm 5452 mm 6052 mm 6652 mm 7252 mm
1640 mm 1940 mm 2240 mm 2540 mm 2840 mm 3140 mm 3440 mm
350 mm
370 mm
100-240 VAC, 50/60 Hz
See system nameplate
16 A breaker with tripping characteristics C or K
1
550 mm
570 mm
650 mm
2100 – 3000 mm
G + I
min. J + 50 mm
min. Q + 100 mm
BAL_K21_EN_3V3_BLA_121-006423019