3.4.3

Emergency stop button

When the emergency stop button is pushed the rotating turnstile is stopped immediately, the
turnstile is released and can be rotated manually.
After resetting the emergency stop button, the preset operating mode will continue.
NOTICE
The turnstile cannot be turned manually on a subfloor door with a geared motor!
3.4.4

BDE-D-KTA control unit

The electronic BDE-D-KTA control unit is a convenient input and output terminal for operat-
ing the door. Clearly arranged buttons enable easy operation of the door modes and naviga-
tion of the drive-specific menu structure. The LCD display with backlight supports users with
logical symbols and text messages and provides information on the state of the door.
3.4.5

Start button

IMPORTANT
In the LOCKED mode, the start button function is disabled after 10 minutes.
By pressing a start button, the turnstile starts and rotates one turn to prevent locking. The start button has no func-
tion in case of power failure.
3.4.6

Information on motion detectors

NOTICE
Moving objects, i.e. loose poster or plants that move in the detection area can trigger an unin-
tentional startup.
Motion detectors are installed on each access side of the door (see "Safety and operating compon-
ents legend").
These motion detectors detect moving persons. If for example, the detection field of a motion detector
is entered in the AUTOMATIC operating mode, the turnstile will start to rotate from the start position.
If the detection field is entered in the CONTINUOUS operating mode, (slow speed) the turnstile will
accelerate from slow speed to walking speed.