  • Page 1 K21 Translation of the original manual...
  • Page 2 Document identification Article nr.: 121-006423019 Version: Publication date: 06/04/2021 Subject to technical modifications Copyright © agtatec ag...
  • Page 3: Table Of Contents

    General definitions of terms........................12 3 Description................................ 13 Graphical overview ..........................13 System description ..........................14 Variants..............................14 Safety features and control elements K21.................... 15 3.4.1 Legend for safety features and control elements................16 3.4.2 Emergency operation key switch ..................... 18 3.4.3...
  • Page 4 Table of contents Lock control unit via key panel......................28 Operation lock via key switch ....................... 28 Key operated switch BDE-V ......................... 29 Revolving door mode..........................29 5.6.1 Special functions selection....................... 29 Sliding door mode..........................30 5.7.1 Selecting special functions....................... 30 Display show cases ..........................
  • Page 5: Table Of Revision

    Table of revision Table of revision General BDE-D status messages and potential troubleshooting Changed text ...............................  37 BAL_K21_EN_3V3_BLA_121-006423019 5 / 44...
  • Page 6: Safety

    Safety Safety Presentation of warning signs Various symbols are used in this guide for easier understanding: NOTICE Useful advice and information to ensure correct and efficient workflow of the system. IMPORTANT Specific details which are essential for trouble-free operation of the system. IMPORTANT Important details which must be read for proper function of the system.
  • Page 7: General Hazards

    Safety General hazards The following section lists hazards that can be caused by the system even when used as intended. To reduce the risk of malfunction, damage to property or injury to persons and to avoid dangerous situations, the safety instructions listed here must be observed. The specific safety instructions in the other sections of this manual must also be observed.
  • Page 8 Safety CAUTION Risk of material damage or injury due to unforeseen opening, closing or turning of the door! a) The door can open, close or turn unexpectedly. This may result in damage to property or injury to persons. ð No persons may be present in the opening area of the system. ð...
  • Page 9: State Of Technology

    Safety DANGER Danger to life due to electric current! a) In case of contact with live parts, there is an immediate danger to life due to electric shock. Damage to or removal of the insulation or individual components can be life-threatening. ð...
  • Page 10: Spare Parts And Liability

    Safety The head protection serves to protect against falling and flying parts and materials. It also protects the head from bumping into hard objects. Protective goggles protect the eyes from flying parts, dust, splinters or splashes. Protective gloves are designed to protect hands from friction, abrasions, punctures or serious injury and from burning caused by contacting hot surfaces.
  • Page 11: General Information

    General information General information Purpose and use of the instructions These instructions are an integral part of the system and enable efficient and safe handling of the sys- tem. In order to ensure proper functioning, the instructions must be accessible at all times and kept in the immediate area of the system.
  • Page 12: General Definitions Of Terms

    General information General definitions of terms The following terms are used in manuals for easier understanding: Term: Explanation: System System describes the door drive of the company Blasi GmbH, Carl- Benz-Str. 5-15, D - 77972 Mahlberg. Whenever instructions refer to a specific design, it will be specifically emphasized in the text.
  • Page 13: Description

    Description Description Graphical overview K21/22-S K21/22-P K21/22-FM With sliding door With pivot wing With fixed glazing Abbreviation Description Abbreviation Description Passage width Clearance height Floor trim height OKFFB Top edge finished floor Installation diameter of floor OKRFB Top edge unfinished floor...
  • Page 14: System Description

    Description System description The revolving door has a full automatic, microprocessor controlled drive system, which can be used in several operating modes. The revolving door has a counter clockwise rotation unit, with fixed side glass panels on each outer side and radial protective sliding wing extensions. These serve as pinch protectors and absorb the ro- tating mass by sliding back and simultaneously stopping the rotational movement when touched.
  • Page 15: Safety Features And Control Elements K21

    Description Safety features and control elements K21 INTERIOR VIEW in the closed position Operating element variations available EXTERIOR INTERIOR INTERIOR Front / Side Front / Side / Back Back BAL_K21_EN_3V3_BLA_121-006423019 15 / 44...
  • Page 16: Legend For Safety Features And Control Elements

    Description EXTERIOR INTERIOR 3.4.1 Legend for safety features and control elements Pos. No. Components Motion detector canopy or floor installation (AKI / AKA) Vertical forward sensor radial protective sliding wing (OP-VLS) 3, 3A, 3B Vertical sensors drum edges (OP-VSS) Horizontal heel protection light barrier SLOW (OP-HSR) Horizontal heel protection light barrier STOP (OP-HSR) Vertical safety strips drum edges (SL-TRK) Vertical safety strip radial protective sliding wing (SL-RSF)
  • Page 17 Description Foot protection sensor radial protective sliding wing Vertical light barriers drum edges Monitoring contact night shield (UW-NAS) Main power switch (UW-HAS) Control unit BDE-D-KTA Key-operated switch BDE-V Key-operated emergency switch Emergency stop switch Disabled person button Start button Key pivot contact Contact mat blocked segment Key-operated switch Sliding door drive STA 20...
  • Page 18: Emergency Operation Key Switch

    Description Plastic manufacturer's logo System nameplate Sticker STOP Sticker Baby carriage / Wheel chair / Mother + Child / Dog Sticker Mother + Child/ Dog Sticker START Sticker Maximum weight Sticker “Opening service trap” Glass label (example) Labelling the glass surface reduces the danger of collision. Transparent wings or wing surfaces must be must be clearly visible, for example, by permanent labelling, appropriate markings or use of coloured materials.
  • Page 19: Emergency Stop Button

    Description 3.4.3 Emergency stop button When the emergency stop button is pushed the rotating turnstile is stopped immediately, the turnstile is released and can be rotated manually. After resetting the emergency stop button, the preset operating mode will continue. NOTICE The turnstile cannot be turned manually on a subfloor door with a geared motor! 3.4.4 BDE-D-KTA control unit...
  • Page 20: Information On Safety Strips

    Description 3.4.7 Information on safety strips CAUTION Risk of destruction Safety edge a) Personal injury and damage to property due to malfunctions on the safety edge ð Do not use pointed or sharp-edged objects when working on the safety edge. ð...
  • Page 21: Wind Trap Switch In Day / Night Operation

    Description 3.5.3 Wind trap switch in day / night operation The switching of the wind trap in day/night operation is carried out via a switch provided by the customer. Daytime operation: The operating mode set on the control unit is executed. Night operation: The carousel moves to the transverse position (sliding door position).
  • Page 22: Night Shield

    Description It can be operated with the key reversing switch. Opening process: the night shield is opened by turning the key reversing switch to the right (see arrow direction) and holding the position. If the night shield is locked electrically, then it will simultaneously unlock.
  • Page 23: Light Switch

    Description 3.5.9 Light switch The lighting can be or is connected to an on-site light switch or controlled by the building control sys- tem to be switched OFF or ON. 3.5.10 Lighting control The lights can be turned on or off via an on-site light switch or over the building control centre. 3.5.11 Air curtain control Direct ventilation to the interior via an air duct built into the doorway.
  • Page 24: Specifications

    Specifications Specifications Dimensions U = interior diameter 3600 mm 4200 mm 4800 mm 5400 mm 6000 mm 6600 mm 7200 mm A = passage width 2005 mm 2347 mm 2688 mm 3030 mm 3371 mm 3713 mm 4055 mm Q = total exterior diameter (incl. 3758 mm 4358 mm 4958 mm 5558 mm 6158 mm 6758 mm 7358 mm canopy) T = exterior diameter (drum wall)
  • Page 25: Electrical Lighting Specifications

    Specifications Electrical lighting specifications High-Power LED-Spots Mains connection Transformer 100-240 VAC Frequency 50-60 Hz Secondary transformer power 120 W Output per luminaire/illuminant 4.5 W Protection class / Insulation class Transformer Degree of protection IP 67 NOTICE The power connection must be installed by a licensed electrician. The power must be able to be shut off via a main switch or residual current circuit breaker (on-site).
  • Page 26: Operation

    Operation Operation NOTICE SLIDING DOOR OPERATION only functions when "SLIDING DOOR OPERATION" has been se- lected on the BDE-D-KTA and when the rotation unit is in the cross position. The systems can be operated by pressing the appropriate buttons on the control units: Revolving door mode selection Control unit Operation...
  • Page 27: Sliding Door Mode Selection

    Operation Control unit Operation BDE-D-KTA for revolving Display Function door operation SLIDING DOOR OPERATION When the rotation unit is positioned in the cross position, various modes of the sliding door are operational. press 2sec. – Press the key for approx. 2 sec. or press 2 times long or 2x quickly.
  • Page 28: Lock Control Unit Via Key Panel

    Operation NOTICE A reduced opening width is also available in the operating modes ONE WAY and PERA- MENTLY OPEN. NOTICE Exiting the sliding door operation and resuming the revolving door operation is done by se- lecting the desired revolving door operation on the control unit BDE-D-KTA. It does not matter what position the wings of the sliding doors are currently in.
  • Page 29: Key Operated Switch Bde-V

    Operation Key operated switch BDE-V Function Symbol Description – By turning the key switch to the right until it stops, the operating mode "Locked" is selected. Locked Locked Varies, depending Varies, depending – By turning the key switch to the left until it stops, the on the preset mode on the preset mode operating mode is changed from "Locked"...
  • Page 30: Sliding Door Mode

    Operation Sliding door mode 5.7.1 Selecting special functions Function Symbol Description – Press key approx. 2 seconds or 2 x briefly in a row. – Sliding door can be used manually. Manual op- – Back to a different operating mode eration –...
  • Page 31: Locking Elements

    Operation Locking elements The revolving door is equipped with an electro-mechanical bistable lock. The lock can be turned on and/or off with the control unit. The rotating inner section (rotation unit) positions itself in front of the passage way of the revolving door and is locked together with the exterior radial-sliding wing. This way the night shield is directly integrated and does not need to be built in separately.
  • Page 32: Accessories

    Operation 5.11 Accessories Timer Switching form AUTOMATIC operating mode to OFF operating mode and back can be done using a timer. Door passage lighting If the normal ambient lighting is not sufficient, then suitable integral lighting must be provided. The quantity and type of lighting required for this revolving door is defined in the list of components or in the construction drawings.
  • Page 33: Servicing And Maintenance

    Servicing and maintenance Servicing and maintenance General remarks According to the legal provision in force, the operating entity of the automatic door is responsible for its maintenance and for the user's safety, as soon as the installation has been handed over. The regular inspection of single elements by the operator requires little time investment and rein- forces the prevention of accidents caused by an inappropriate use of the door.
  • Page 34: Monthly Inspection Work To Be Carried Out By The Operating Company

    Servicing and maintenance Monthly inspection work to be carried out by the operating company Test / Inspection Procedure Expected results Motion detector – Walk towards the door at normal – The sensor must cover the entire speed (from the inside and out- passage width side) –...
  • Page 35: Cleaning And Care

    Servicing and maintenance Visual inspection of the instructions – Verify that all labels are present – All labels must be present, legible and labeling (buttons / switches) and legible. and firmly applied. Visual inspection of the glass label – Verify that the label is present. –...
  • Page 36: Troubleshooting

    Troubleshooting Troubleshooting Conduct during malfunctions If a malfunction occurs in the revolving door, it will appear on the control unit display. Operational malfunctions of the revolving door are shown on the BDE-D-KTA control unit of the re- volving door and operational malfunctions of the sliding door on the BDE-D-STA of the sliding door. IMPORTANT In all operating modes, with the exception of "locked", the radial protective sliding wing can be pushed open manually to escape the rotor chamber in the case of a malfunction.
  • Page 37: General Bde-D Status Messages And Potential Troubleshooting

    Troubleshooting 7.1.3 General BDE-D status messages and potential troubleshooting Abbreviation / Meaning Symbol Status or error number General instructions A service technician is required for resetting the error display. After removing an error, no auto- matic reset happens. No serious malfunction but only a warning message. Despite an active error the door can be provisionally locked as follows: –...
  • Page 38 Troubleshooting SSK aktive STA/DFA: The signal on the key-operated contact is permanently active. – Check the SSK switch and wiring/connections. – The response time for the error can be configured or the error message can be disabled (see Parameter → Miscellaneous → Alarm display → Time activation).
  • Page 39 Troubleshooting SL-RSF1 / RSF1 > Safety strip activated or radial protective sliding wing displaced for longer 60s active than 60 sec. – Check that no objects are activating the safety strip and that the radial protective sliding wing is not displaced. SL-RSF2 / RSF2 >...
  • Page 40: Restarting The Control Units

    Troubleshooting SL-VSR1 error Safety strip radial fixed wing 1 has internal evaluation error. – Press safety strip. – If evaluation error does not disappear, contact your service centre. SL-VSR2 error Safety strip radial fixed wing 2 has internal evaluation error. –...
  • Page 41: Restarting The Revolving Door Control

    Troubleshooting 7.2.1 Restarting the revolving door control Procedure BDE-D Display Function Press until the BDE-D dis- Depending on the mode selected. play appears. Press key briefly, if no re- Previously set oper- There is no restart. start (no) has to be per- ating mode The system carries out the previ- formed.
  • Page 42: Function During A Power Failure

    Troubleshooting Function during a power failure CAUTION Danger of people being trapped inside the turnstile. a) Bruises and contusions through from the turnstile wing. ð Visual inspection, check whether people are trapped inside. In the event of a power failure, the rotation is stopped immediately and the turnstile is then freely ro- tatable.
  • Page 43: Taking Out Of Service And Disposal

    Taking out of service and disposal Taking out of service and disposal Decommissioning When shutting down or taking out of service, the system is disconnected from the mains supply and any existing battery is unplugged. NOTICE After each temporary shutdown a new commissioning must be carried out. Dismantling and disposal IMPORTANT All machine parts must be sorted by type of material and disposed of according to...
  • Page 44 Denmark www.record-danmark.dk España www.record.es France www.record.fr Great Britain www.recorduk.co.uk Malaysia www.recorddoors.my Polska pl.record.global Schweiz www.record.ch Sverige www.record.se Türkiye tr.record.global United States www.recorddoors.com record global export www.record.global record Group www.record.group Subject to technical modifications Copyright © agtatec ag No. 121-006423019...