CEILING MOUNT
PIR TIMER
374B-1
3 wire
The Ceiling Mount PIR Timer (3 wire)
is part of the Elkay family of switches,
timers and detectors which save
energy and increase convenience in
and around your home, garden
or premises.
Rating at 240V ac 50Hz
All load types 10A
Time Delay: 2min - 1 hour
Sensitivity adjustment
Auto and manual Lux Sensor for
daylight control
Surface and flush mounted options
Interchangeable white / chrome fascias
Usage
The PIR sensor has been designed to switch
lighting, heating and ventilation loads up
to 10A. The unit is switched on by the
detection of moving infra red heat within
a specified range. When infra red heat, such
as a moving body, is no longer detected,
the unit will switch off the load after the
adjustable time period has elapsed.
If infra red heat is detected again during the
timing period, the timing sequence will
restart. The unit has a lux level adjustment
and Auto Lux function, which measures
the ambient light levels and prevents lighting
/
Test mode
being switched on, when there is sufficient
lighting in the room. There is sensitivity
adjustment and test mode function added
for your convenience.
IMPORTANT
a power factor correction
capacitor of 4 microfarads may be
required when switching low wattage
loads, e.g. LED loads. the capacitor is fitted
across switch live and neutral supplies of
suitable Elkay capacitors can be found at
your stockist (ref. pfcc-1). Do not insulation
resistance test this product. Remove before
testing or test circuit prior to fitting.
BDH
BROOK DESIGN
HARDWARE LTD
BDH
BR
HA

Advertisement

loading

Summary of Contents for Elkay 374B-1

  • Page 1 CEILING MOUNT PIR TIMER 374B-1 3 wire The Ceiling Mount PIR Timer (3 wire) is part of the Elkay family of switches, timers and detectors which save energy and increase convenience in and around your home, garden or premises. Rating at 240V ac 50Hz •...
  • Page 2 INSTRUCTION GUIDE CEILING MOUNT PIR TIMER – 3 WIRE Diagram 1 Diagram 2 Removing the Sensor from Surface Mount Box. CEILING CEILING CEILING FLOOR FLOOR FLOOR 7-10 metres approx . 7-10 metres approx . 7-10 metres approx 7-10 metres approx . 7-10 metres approx Squeeze the housing...
  • Page 3 INSTRUCTION GUIDE CEILING MOUNT PIR TIMER – 3 WIRE Installation Steps conduit terminal box and return connected IT IS ESSENTIAL THAT YOU FOLLOW PIR into surface mount cup. CLOSELY STEPS 1 TO 8 OF THE MOUNTING AND INSTALLATION INSTRUCTIONS Step 4 BELOW.
  • Page 4 For further help or assistance or information on this or other products in the range person or a qualified electrician and should be please call the Elkay Technical team on +44 (0)28 9061 6505. Please call the fitted to current IEE wiring regulations BS 7671.