5.2

Description of parameters

W = Factory settings: Basic drive (FP)
PARAMETER
DRIVING CYCLE
→ Closing speed
→ Opening speed
TIME DELAYS OPEN
→ Time delay open
→ Time delay SSK
NOTICE
The open duration can be reduced when sensors are used which keep the door open, for ex-
ample, Time delay.
DRIVE
→ Opening angle
BAL_C127_X_SU_H-B_OFFSET_EN_1V1_REC_121-006454632
W
Comment
18
Driving speed when closing the door.
0 = lowest speed
40 = highest speed
– The maximum reachable speed depends on the driven distance
(door width) and the acceleration setting.
20
Change value to 20 after reset!
(36)
Driving speed of the opening door.
0 = lowest speed
40 = highest speed
– The maximum speed reachable depends upon the opening angle
and the acceleration setting.
– DIN: > 1.5 s <4 s
2
Determines the minimum time for which a door stays open after it has
been opened by a type AKA, AKI or automatic triggering signal.
0..20 = 0 to 20 seconds, 1 s increments
21..40 = 22 to 60 seconds, 2 s increments
– The hold-open time starts only after all trigger and safety signals
have been made in the closing direction.
4
Determines the minimum time for which a door stays open after it has
been opened by a type SSK triggering signal.
0..20 = 0 to 20 seconds, increments 1 s
21..40 = 22 to 60 seconds, increments 2 s
– The hold-open time starts only after all trigger and safety signals
have been made in the closing direction.
35
The opening angle is read during the learning cycle and corresponds to
the value 40.
0 = minimum opening angle
40 = maximum opening angle
– DIN: min. 95°
5
Operation
21 / 32

Hide quick links: